Transcranial sonographic assessment of the third ventricle in neuro-ICU patients to detect hydrocephalus: a diagnostic reliability pilot study

Autor: Paul Bory, Flora Djanikian, Kevin Chalard, Frédéric Greco, Pierre-François Perrigault, Rémy Widehem, Samir Jaber, Frederique Pavillard, Alexandre Mas, Gerald Chanques, Julie Carr, Nicolas Molinari
Přispěvatelé: Hôpital Gui de Chauliac, Université Montpellier 1 (UM1)-Centre Hospitalier Régional Universitaire [Montpellier] (CHRU Montpellier), CHU Saint-Eloi, Institut Montpelliérain Alexander Grothendieck (IMAG), Université de Montpellier (UM)-Centre National de la Recherche Scientifique (CNRS), Hôpital de la Colombière, Physiologie & médecine expérimentale du Cœur et des Muscles [U 1046] (PhyMedExp), Institut National de la Santé et de la Recherche Médicale (INSERM)-Université de Montpellier (UM)-Centre National de la Recherche Scientifique (CNRS), Centre Hospitalier Régional Universitaire [Montpellier] (CHRU Montpellier), Université de Montpellier (UM), Hôpital Gui de Chauliac [Montpellier], MORNET, Dominique, Hôpital Saint Eloi (CHRU Montpellier), Université de Montpellier (UM)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS)
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Zdroj: Annals of Intensive Care
Annals of Intensive Care, SpringerOpen, 2021, 11 (1), pp.69. ⟨10.1186/s13613-021-00857-x⟩
Annals of Intensive Care, Vol 11, Iss 1, Pp 1-11 (2021)
ISSN: 2110-5820
Popis: Background Transcranial sonography is a point-of-care tool recommended in intensive care units (ICU) to monitor brain injured patients. Objectives of the study was to assess feasibility and reliability of the third ventricle (V3) diameter measurement using transcranial sonography (TCS) compared to brain computed-tomography (CT), the gold standard measurement, and to measure the TCS learning curve. Design: prospective study, in a 16-bed neurological ICU in an academic hospital. Every consecutive brain injured adult patient, who required a brain CT and TCS monitoring were included. The V3 diameter was blindly measured by TCS and CT. Intraclass correlation coefficient (ICC) and Bland–Altman plot were used to assess the reliability and agreement between TCS and CT V3 measurements. Diagnosis performance of the V3 diameter using TCS to detect hydrocephalus was measured. Absolute difference between V3 measurement by residents and experts was measured consecutively to assess the learning curve. Results Among the 100 patients included in the study, V3 diameter could be assessed in 87 patients (87%) from at least one side of the skull. Both temporal windows were available in 70 patients (70%). The ICC between V3 diameter measured by TCS and CT was 0.90 [95% CI 0.84–0.93] on the right side, and 0.92 [0.88–0.95] on the left side. In Bland–Altman analysis, mean difference, standard deviation, 95% limits of agreement were 0.36, 1.52, − 2.7 to 3.3 mm, respectively, on the right side; 0.25, 1.47, − 2.7 to 3.1 mm, respectively, on the left side. Among the 35 patients with hydrocephalus, V3 diameters could be measured by TCS in 31 patients (89%) from at least one side. Hydrocephalus was, respectively, excluded, confirmed, or inconclusive using TCS in 35 (40%), 25 (29%) and 27 (31%) of the 87 assessable patients. After 5 measurements, every resident reached a satisfactory measurement compared to the expert operator. Conclusion TCS allows rapid, simple and reliable V3 diameter measurement compared with the gold standard in neuro-ICU patients. Aside from sparing irradiating procedures and transfers to the radiology department, it may especially increase close patient monitoring to detect clinically occult hydrocephalus earlier. Further studies are needed to measure the potential clinical benefit of this method. Trial registration: ClinicalTrials.gov ID: NCT02830269.
Databáze: OpenAIRE