Oxidative Cleavage-Based Three-Dimensional DNA Biosensor for Ratiometric Detection of Hypochlorous Acid and Myeloperoxidase
Autor: | Bo Liu, De-Ming Kong, Xiao Jing, Dong-Xia Wang, Jia-Yi Ma, Jing Wang, An-Na Tang, Dan-Ye Chen |
---|---|
Rok vydání: | 2021 |
Předmět: |
chemistry.chemical_classification
biology Hypochlorous acid Chemistry Biosensing Techniques DNA Hydrogen Peroxide Oxidative phosphorylation Hypochlorous Acid Analytical Chemistry Oxidative Stress chemistry.chemical_compound Enzyme Biochemistry Myeloperoxidase Nucleic acid biology.protein Biomarker (medicine) Biosensor Peroxidase |
Zdroj: | Analytical Chemistry. 93:16231-16239 |
ISSN: | 1520-6882 0003-2700 |
DOI: | 10.1021/acs.analchem.1c04113 |
Popis: | Methods to detect and quantify disease biomarkers with high specificity and sensitivity in biological fluids play a key role in enabling clinical diagnosis, including point-of-care testing. Myeloperoxidase (MPO) is an emerging biomarker for the detection of inflammation, neurodegenerative diseases, and cardiovascular disease, where excess MPO can lead to oxidative damage to biomolecules in homeostatic systems. While numerous methods have been developed for MPO analysis, most techniques are challenging in clinical applications due to the lack of amplification methods, high cost, or other practical drawbacks. Enzyme-linked immunosorbent assays are currently used for the quantification of MPO in clinical practice, which is often limited by the availability of antibodies with high affinity and specificity and the significant nonspecific binding of antibodies to the analytical surface. In contrast, nucleic acid-based biosensors are of interest because of their simplicity, fast response time, low cost, high sensitivity, and low background signal, but detection targets are limited to nucleic acids and non-nucleic acid biomarkers are rare. Recent studies reveal that the modification of a genome in the form of phosphorothioate is specifically sensitive to the oxidative effects of the MPO/H2O2/Cl- system. We developed an oxidative cleavage-based three-dimensional DNA biosensor for rapid, ratiometric detection of HOCl and MPO in a "one-pot" method, which is simple, stable, sensitive, specific, and time-saving and does not require a complex reaction process, such as PCR and enzyme involvement. The constructed biosensor has also been successfully used for MPO detection in complex samples. This strategy is therefore of great value in disease diagnosis and biomedical research. |
Databáze: | OpenAIRE |
Externí odkaz: |