Contrasting Results from Two Commercial Kits Testing for the Presence of Clostridium perfringens Enterotoxin in Feces from Norovirus-Infected Human Patients

Autor: Asako Nakamura, Arimi Nakamoto, Yuki Carle, Shuji Fujimoto, Shinichiro Hirai, Yoshiyuki Aihara, Hiromi Nagaoka, Hiroaki Shigemura, Taisei Ishioka, Koichi Murakami, Akiko Kubomura, Kazunori Oishi, Hirokazu Kimura, Takumi Motoya
Rok vydání: 2020
Předmět:
Zdroj: Clinical laboratory. 66(5)
ISSN: 1433-6510
Popis: Background Detection of Clostridium perfringens enterotoxin (CPE) is critical for disease surveillance; however, commercial testing kits produce contrasting results. Methods We examined the cause of the differing results from a reversed passive latex agglutination (RPLA) assay (PET-RPLA Toxin Detection Kit) and an enzyme-linked immunosorbent assay (C. perfringens Enterotoxin ELISA Kit) using 73 human norovirus-positive fecal samples from gastroenteritis patients across 22 episodes in Japan. Results CPE was detected in 39/73 samples using the RPLA method; however, ELISA-based examination of 10 RPLA-positive samples produced negative results. Moreover, cpe was not detected in any of the RPLA-positive (n = 32) or -negative (n = 5) samples, and C. perfringens was only isolated from one RPLA-positive sample. Conclusions An ELISA-based testing approach may be more reliable than RPLA assays for CPE detection from human fecal samples. These findings may also be applicable to the detection of other foodborne diseases.
Databáze: OpenAIRE