Comparison of the iCare, Tono-Pen, non-contact airpuff, and Goldmann applanation tonometers in eyes with corneal edema after penetrating keratoplasty
Autor: | Catherine Jui Ling Liu, Shih Jung Yeh, Mei Ju Chen, Ko Hua Chen, Tung Mei Kuang |
---|---|
Rok vydání: | 2021 |
Předmět: |
Male
medicine.medical_specialty Intraocular pressure genetic structures Manometry Tono pen 030204 cardiovascular system & hematology law.invention 03 medical and health sciences 0302 clinical medicine Corneal edema law Ophthalmology parasitic diseases medicine Humans In patient Intraocular Pressure Aged Keratometer Corneal curvature business.industry Corneal Edema Goldmann Applanation Tonometer Glaucoma General Medicine Middle Aged eye diseases 030220 oncology & carcinogenesis Female sense organs Slit lamp biomicroscopy business Keratoplasty Penetrating |
Zdroj: | Journal of the Chinese Medical Association. 84:320-325 |
ISSN: | 1726-4901 |
DOI: | 10.1097/jcma.0000000000000476 |
Popis: | BACKGROUND To compare the utility of the iCare, Tono-Pen, and non-contact airpuff (NCT) tonometers with the Goldmann applanation tonometer (GAT) for measuring intraocular pressure (IOP) in patients with corneal edema after penetrating keratoplasty (PKP) and to assess the effects of central corneal thickness (CCT) and corneal curvature (CC) on IOP measurements. METHODS Thirty-two eyes of 27 patients with corneal edema after PKP due to corneal abnormalities and 43 control eyes of 30 patients with normal corneas were recruited. Before IOP measurements, all patients underwent a baseline examination, including auto-refraction, keratometry, slit lamp biomicroscopy, and CCT measurement. IOP was measured using the devices in the same order: first the NCT, followed by the iCare, Tono-Pen, and GAT. The differences between the iCare, Tono-Pen, NCT, and GAT were calculated with repeated-measures analysis of variance. The Bland-Altman method was used to assess the agreement between the iCare, Tono-Pen, and NCT versus the GAT. The influences of CCT and CC on IOP measurement were evaluated by correlation analysis using Pearson's correlation coefficient. RESULTS Mean IOP measurements were significantly higher with the NCT and Tono-Pen than with the GAT in the PKP and control groups. When compared with GAT, iCare showed significantly higher IOP readings in the control group, but the IOP readings did not differ between the iCare and GAT in the PKP group. Poor agreement was noted between the NCT and GAT in both groups. The Tono-Pen showed clinically acceptable agreement with GAT in control eyes and poor agreement in PKP eyes. The agreement between the iCare and GAT appeared to be clinically acceptable in both groups. Correlation analysis of the results from control eyes showed that the IOP measurements with the GAT and NCT were weakly related to CCT and moderately correlated with CC. The iCare IOP readings were weakly correlated with CCT and CC. CONCLUSION In the PKP group, the NCT and Tono-Pen significantly overestimated IOP, whereas the iCare IOP readings were similar to those obtained using the GAT. Poor agreement was noted between the NCT and GAT as well as between the Tono-Pen and GAT, but the iCare showed clinically acceptable agreement with GAT. In normal corneas, the GAT, NCT, and iCare were affected by CCT and CC. The iCare tonometer was less affected by corneal edema than were the NCT and the Tono-Pen. The iCare appears to be a useful device for IOP measurement in eyes with corneal edema after PKP. |
Databáze: | OpenAIRE |
Externí odkaz: |