Rehabilitative ultrasound imaging of the levator scapula muscle at rest and during contraction: Technical description and reliability
Autor: | Fariba Khosravi, Noureddin Karimi, Leila Rahnama, Mark D. Geil, Mahsa Rahnama, Mohsen Amiri |
---|---|
Rok vydání: | 2020 |
Předmět: |
Complementary and Manual Therapy
Orthodontics Adult Contraction (grammar) business.industry Interclass correlation Muscles Rehabilitation Ultrasound Reproducibility of Results Physical Therapy Sports Therapy and Rehabilitation Isometric exercise Scapula Young Adult Complementary and alternative medicine Isometric Contraction Ultrasound imaging Medicine Humans business Rest (music) Reliability (statistics) Muscle Contraction Ultrasonography |
Zdroj: | Journal of bodywork and movement therapies. 28 |
ISSN: | 1532-9283 |
Popis: | Background Altered scapular muscle activity is associated with abnormal scapular motions and shoulder pain. Hence, quantification of these activities is a challenging issue. Objectives: The purposes of this study were to establish the reliability of measuring levator scapula muscle thickness and to examine how thickness of this muscle changes with contraction. Methods Twenty-one asymptomatic individuals (mean age 22.29 ± 2.17 years) participated in this study. Three separate ultrasound images of the levator scapula muscle were captured at the neck-shoulder junction at rest and during a loaded isometric contraction. The procedures were repeated twice, four to seven days apart to establish intra-rater test-retest reliability. Interclass correlation coefficients (ICC) and standard error of measurement (SEM) were used to determine the reliability, and a paired t-test was performed to examine the difference in muscle thickness between two conditions. Results The results demonstrated that intra-examiner reliability was good at rest (ICC = 0.88, SEM = 1.16 mm) and excellent during loaded isometric contraction (ICC = 0.95, SEM = 0.91 mm). Furthermore, the thickness of levator scapula muscle significantly increased from rest to the loaded isometric contraction (Effect size = 1.99, P Conclusion This study demonstrates that the thickness of the levator scapula muscle can be measured reliably at the neck-shoulder junction. Furthermore, ultrasound measures can reliably detect changes in muscle thickness from rest to a contracted state. Therefore, if the need exists to evaluate muscle morphology before and after any treatment strategy, thickness measurement of levator scapula can be determined reliably using ultrasound. |
Databáze: | OpenAIRE |
Externí odkaz: |