An Early Canadian Experience with the Correx Automated Coring and Apical Connector Device for Aortic Valve Bypass
Autor: | Bob Kiaii, H. Al-Habib, Corey Adams, Hussein A. Al-Amodi, Christopher L. Tarola, Linrui Ray Guo |
---|---|
Rok vydání: | 2016 |
Předmět: |
Male
Pulmonary and Respiratory Medicine Aortic valve Canada medicine.medical_specialty Standard of care medicine.medical_treatment 030204 cardiovascular system & hematology 03 medical and health sciences 0302 clinical medicine Valve replacement Internal medicine medicine Humans Aged Aged 80 and over Salvage Therapy Apicoaortic Conduit Cardiopulmonary Bypass business.industry Anastomosis Surgical Aortic Valve Stenosis Equipment Design General Medicine Middle Aged medicine.disease Coring Surgery Treatment Outcome medicine.anatomical_structure Thoracotomy 030228 respiratory system Aortic valve stenosis cardiovascular system Cardiology Female Cardiology and Cardiovascular Medicine business |
Zdroj: | Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 11:434-438 |
ISSN: | 1559-0879 1556-9845 |
DOI: | 10.1097/imi.0000000000000322 |
Popis: | Objective Aortic valve replacement is the standard of care for severe, symptomatic aortic valve stenosis (AS); however, anatomy or preexisting comorbidities may preclude conventional or alternative transcatheter approaches. Aortic valve bypass (AVB) may be performed as a salvage procedure for the relief of symptomatic aortic stenosis in patients who are not suitable candidates for aortic valve replacement. Methods At our institution, seven patients underwent AVB using the Correx automated coring and apical connector system. All patients had severe AS with New York Heart Association functional class 3 symptoms and were not candidates for conventional or transcatheter approaches. Via a left anterolateral thoracotomy to access the descending aorta and left ventricular apex, we used the Correx system (Correx, Waltham, MA USA) to anastomose a valve conduit to the left ventricular apex proximally and the descending aorta distally. Three patients required cardiopulmonary bypass. Results In all seven patients, the automated coring and apical connector was successfully deployed. There were two in-hospital deaths in this series. Immediately postoperatively and at 3 months, there was a significant reduction in mean and peak valve gradients, and all surviving patients performed at New York Heart Association functional class 1. Conclusions Aortic valve bypass seems to be an acceptable alternative for the treatment of severe AS in high-risk patients who are not candidates for aortic valve replacement. The Correx automated system may improve the clinical applicability and surgical repro-ducibility of AVB in appropriately selected patients in which conventional or transcatheter aortic valve replacement is not a feasible options. |
Databáze: | OpenAIRE |
Externí odkaz: |