Design and application of model for training ultrasound-guided vascular cannulation in pediatric patients
Autor: | J.F. Loro-Ferrer, J.M. López-Álvarez, J.M. Limiñana-Cañal, O. Pérez-Quevedo |
---|---|
Rok vydání: | 2015 |
Předmět: |
medicine.medical_specialty
Catheterization Central Venous Small diameter Perforation (oil well) Population Vascular access Critical Care and Intensive Care Medicine Models Biological 03 medical and health sciences 0302 clinical medicine 030202 anesthesiology medicine Humans education Child Ultrasonography education.field_of_study business.industry Small children Infant Newborn Infant 030208 emergency & critical care medicine Ultrasound guided Pediatric patient Child Preschool Ultrasound imaging Radiology business |
Zdroj: | Medicina intensiva. 40(6) |
ISSN: | 1578-6749 |
Popis: | Central vascular cannulation is not a risk-free procedure, especially in pediatric patients. Newborn and infants are small and low-weighted, their vascular structures have high mobility because of tissue laxity and their vessels are superficial and with small diameter. These characteristics, together with the natural anatomical variability and poor collaboration of small children, make this technique more difficult to apply. Therefore, ultrasound imaging is increasingly being used to locate vessels and guide vascular access in this population. Objective (a) To present a model that simulates the vascular system for training ultrasound-guided vascular access in pediatrics patients; (b) to ultrasound-guided vascular cannulation in the model. Results The model consisted of two components: (a) muscular component: avian muscle, (b) vascular component: elastic tube-like structure filled with fluid. 864 ecoguided punctures was realized in the model at different vessel depth and gauge measures were simulated, for two medical operators with different degree of experience. The average depth and diameter of vessel cannulated were 1.16 (0.42) cm and 0.43 (0.1) cm, respectively. The average number of attempts was of 1.22 (0.62). The percentage of visualization of the needle was 74%. The most frequent maneuver used for the correct location, was the modification of the angle of the needle and the relocation of the guidewire in 24% of the cases. The average time for the correct cannulations was 41 (35.8) s. The more frequent complications were the vascular perforation (11.9%) and the correct vascular puncture without possibility of introducing the guidewire (1.2%). The rate of success was 96%. Conclusions The model simulates the anatomy (vascular and muscular structures) of a pediatric patient. It is cheap models, easily reproducible and a useful tool for training in ultrasound-guided puncture and cannulation. |
Databáze: | OpenAIRE |
Externí odkaz: |