Favorable results from a prospective evaluation of 200 patients with large hiatal hernias undergoing LINX magnetic sphincter augmentation

Autor: Rachel Heidrick, Kate Freeman, Francis Paul Buckley, Stephanie Doggett, Reginald Bell
Jazyk: angličtina
Rok vydání: 2017
Předmět:
Zdroj: Surgical Endoscopy
ISSN: 1432-2218
0930-2794
Popis: Introduction Magnetic sphincter augmentation (MSA) of the lower esophageal sphincter restores the antireflux barrier in patients with hiatal hernias ≤3 cm. We performed a prospective study in patients undergoing MSA with the LINX device during repair of paraesophageal and hernias over 3 cm axial component. Methods and procedures Multicenter, prospective study of consecutive patients treated with MSA at the time of repair of hiatal hernias >3 cm. Results 200 patients (110 female) were treated between March 2014 and February 2017 via laparoscopic hernia repair and MSA. Mean age was 59.5 years, mean BMI 29.4. 40% had esophagitis, 20% intestinal metaplasia, 72 of 77 tested had abnormal pH studies. Preoperative PPI use was reported by 87%. Eighteen patients had prior hiatal hernia/fundoplication. All had normal function. 78% of patients had axial hiatal hernia ≥5 cm or large paraesophageal component. Mean operative time was 81 min (38–193), EBL was 10 cc. Non-permanent mesh reinforcement of hiatal repair was performed in 83% of the patients. There were two readmissions for dehydration; 2 patients with pulmonary embolism, and 1 patient with cardiac ischemia. Nineteen patients required dilation. 156 pts were followed at a median of 8.6 months. GERD-HRQL scores improved from 26 preoperatively to 2 postoperatively. Complete PPI independence was achieved in 94% (147/156). Videoesophagram in 51 patients at median 11 months found 3 asymptomatic hernias 3 cm hernias undergoing MSA with hiatoplasty resulted in favorable outcomes with median of 9 months follow-up. Comparing this to published reports of MSA in patients with
Databáze: OpenAIRE