Validity and metric of MiniMental Parkinson and MiniMental State Examination in Parkinson's disease

Autor: Ubaldo Bonuccelli, D. De Gaspari, Nadia Morielli, Chiara Siri, Michele Poletti, Marco Vista, Angelo Antonini, Cristina Mapelli, Ildebrando Appollonio, Valeria Isella, Lucia Picchi, Andrea Greco, Alessandro Napolitano, Giovanni Pezzoli
Přispěvatelé: Isella, V, Mapelli, C, Morielli, N, De Gaspari, D, Siri, C, Pezzoli, G, Antonini, A, Poletti, M, Bonuccelli, U, Picchi, L, Napolitano, A, Vista, M, Greco, A, Appollonio, I
Jazyk: angličtina
Rok vydání: 2013
Předmět:
Settore M-PSI/01 - Psicologia Generale
Male
medicine.medical_specialty
Neurology
Parkinson's disease
Psychometrics
Dermatology
Audiology
Neuropsychological Tests
M-PSI/02 - PSICOBIOLOGIA E PSICOLOGIA FISIOLOGICA
Perceptual Disorders
Executive Function
MiniMental Parkinson
Parkinson’s disease
Dementia
MiniMental State Examination
medicine
80 and over
Humans
Psychiatry
Aged
Aged
80 and over

MED/26 - NEUROLOGIA
Analysis of Variance
Receiver operating characteristic
Parkinson's disease
PD
Mini Mental
MMSE
MMP
metric
validity
dementia rating scale
DRS

Reproducibility of Results
Parkinson Disease
General Medicine
Middle Aged
medicine.disease
M-PSI/03 - PSICOMETRIA
Multicenter study
Convergent validity
ROC Curve
Psychiatry and Mental Health
Space Perception
Cognition Disorders
Female
Mental Status Schedule
Neurology (clinical)
2708
Metric (unit)
Psychology
Popis: The MiniMental Parkinson (MMP) has been derived from the MiniMental State Examination (MMSE) for the screening of cognitive impairment in Parkinson’s disease by adding subtests that were focused on executive and visuo-spatial impairment more than on memory or language deficits. In this multicenter study, the psychometric and validity properties of the MMP have been evaluated in 69 cognitively intact and 52 cognitively impaired patients with Parkinson’s disease, classified according to their performance at the Dementia Rating Scale. The MMP showed better metrics and convergent validity, and higher screening ability. However, its performance was not fully satisfying in terms of data distribution, coefficient of variation and specificity, and Receiver Operating Characteristic curves did not show clear cut superiority of either scale at their best sensitivity–specificity trade off. The MMP seems to be slightly preferable to the MMSE only at a cut off that favours sensitivity with respect to specificity, for screening purposes. The test is simple and quick, but has limitations in terms of validity.
Databáze: OpenAIRE