Eficácia das tecnologias de bloqueio dos tubos dentinários para tratamento da hipersensibilidade dentinária em pacientes periodontais – estudo piloto
Autor: | Fabiano Vieira Vilhena, Adriana Campos Passanezi Sant'Ana, Carla Andreotti Damante, Mariana Schützer Ragghianti Zangrando, Flavia Maria Ravagnani Neves Cintra, Maria Laura Bignotto Bigotto, Giovanna Fernanda Favero Silva |
---|---|
Rok vydání: | 2021 |
Předmět: |
Doença periodontal
Enfermedad periodontal dentin hypersensitivity root exposure periodontal disease periodontal treatment desensitizing agents Visual analogue scale Hipersenbilidad dentinária Dentistry Desensitizing agents law.invention Scaling and root planing Randomized controlled trial law medicine Dentifrice General Environmental Science Mild pain Agentes dessensibilizantes business.industry PERIODONTITE Agente dessensibilizante Repeated measures design hipersensibilidade dentinaria exposição radicular doença periodontal tratamento periodontal agentes dessensibilizantes medicine.disease hipersensibilidad dentinaria exposición radicular enfermedad periodontal tratamiento periodontal agentes desensibilizantes Clinical trial General Earth and Planetary Sciences Dentin hypersensitivity Periodontal disease Hipersensibilidade dentinária business |
Zdroj: | Repositório Institucional da USP (Biblioteca Digital da Produção Intelectual) Universidade de São Paulo (USP) instacron:USP Research, Society and Development; Vol. 10 No. 13; e35101320398 Research, Society and Development; Vol. 10 Núm. 13; e35101320398 Research, Society and Development; v. 10 n. 13; e35101320398 Research, Society and Development Universidade Federal de Itajubá (UNIFEI) instacron:UNIFEI |
ISSN: | 2525-3409 |
Popis: | Periodontal patients often report dentin hypersensitivity (DH) caused by root surface exposure or periodontal treatment. Tubular blocking technologies in toothpastes are effective for pain relief, but no specific chemical/physical agent has been reported for periodontal patients. This double-blind randomized clinical trial compared the effects of three technologies in reducing DH in periodontal patients. Eighteen (18) participants were randomly assigned into three groups: SEN (NOVAMIN technology); REG (REFIX technology); REGK (REFIX technology + potassium citrate). Periodontal patients presenting with DH were evaluated at 6 moments: T1 and T2 - immediately before and after scaling and root planing procedures (SRP); T3 - after polishing sensitive areas with their assigned dentifrice and T4, T5, T6 - after 2, 4 and 8 weeks of SRP respectively. Sensitivity was assessed by air blast (Schiff scale) and patients’ perceptions using the visual analogue scale (VAS). Data were analyzed by two-way repeated measures ANOVA complemented by the Tukey test with significance set at 5% (p |
Databáze: | OpenAIRE |
Externí odkaz: |