High intra- and inter-observer reliability of planning implant size in MRI-based patient-specific instrumentation for total knee arthroplasty
Autor: | Dieuwertje M J Theeuwen, Edwin J. P. Jansen, Emil H. van Haaren, Nanne P. Kort, Daphne A. L. Schoenmakers, Martijn G. M. Schotanus, Roel P. M. Hendrickx |
---|---|
Rok vydání: | 2020 |
Předmět: |
medicine.medical_specialty
Knee Joint Intraclass correlation Total knee arthroplasty Prosthesis Design Patient Care Planning Inter observer reliability Intraclass correlation coefficients Implant size medicine Humans Knee Orthopedics and Sports Medicine Femur Arthroplasty Replacement Knee Reliability (statistics) Observer Variation Tibia Patient-specific instrumentation business.industry Orthopedic Surgeons Magnetic Resonance Imaging Patient specific instrumentation Orthopedic surgery Pre-operative planning Surgery Implant Knee Prosthesis business Nuclear medicine |
Zdroj: | Knee Surgery, Sports Traumatology, Arthroscopy |
ISSN: | 1433-7347 0942-2056 |
Popis: | Purpose Patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) uses individually designed disposable guides to determine intraoperative bone cuts. The manufacturer provides the surgeon with proposed planning which can be modified and should be approved by the surgeon before the guides are produced. This study aims to assess the intra- and inter-observer reliability among preoperative planning by orthopaedic surgeons using PSI. The authors hypothesize a high intra- and inter-observer reliability in planning TKA using PSI. Methods Four orthopaedic surgeons modified and approved 40 preoperative MRI-based PSI plannings three times. The surgeons were blinded to their own and each other’s results. Intra- and inter-observer reliability was obtained for planned implant size, resection, and position of the implant. Results Intra-observer reliability Intraclass Correlation Coefficients (ICC) were excellent for femoral and tibial implant size with a range of 0.948–0.995 and 0.919–0.988, respectively. Inter-observer reliability for femoral and tibial implant size showed an ICC range of 0.953–0.982 and 0.839-0.951, respectively. Next to implant size, intra- and inter-observer reliability demonstrated good to an excellent agreement (ICC > 0.75) for 7 out of 12 remaining parameters and 6 out of 12 remaining parameters, respectively. Conclusion Preoperative planning of TKA implant size using MRI-based PSI showed excellent intra- and inter-observer reliability. Further research on the comparison of predicted implant size preoperatively to intraoperative results is needed. |
Databáze: | OpenAIRE |
Externí odkaz: |