Popis: |
Measurements of the local toroidal magnetic field have been achieved on the helicity injected tokamak (HIT) using the transient internal probe (TIP). HIT is a low aspect (a=1.5, R=0.35 m) ratio tokamak designed to study steady state current drive. The TIP diagnostic involves accelerating a small diamond clad magneto-optic probe through the plasma at high velocities (∼2 km/s) using a light gas gun. The local field is obtained by illuminating the probe with a laser and measuring the amount of Faraday rotation in the reflected beam. Measurements were conducted using unclad magneto-optic probes directed along a chord tangent to the toroidal field. Plasma conditions were typically ne∼7×1019 m−3 and Te∼40–80 eV. Measurement uncertainty is less than 2%. No changes in plasma parameters were observed during the first 200 ms (∼40 cm) of probe travel in the plasma. A temporary dip in plasma current, probably due to ablation of the retroreflecting material on the probe, is observed as the probe exits the plasma. Dens... |