Brain stem electric response audiometry in neonates with hyperbilirubinemia
Autor: | S. B. S. Mann, Anil Narang, M. Raghunathan, Vineet Bhandari, O. N. Bhakoo |
---|---|
Rok vydání: | 1993 |
Předmět: |
Male
Pathology medicine.medical_specialty Electric response audiometry Bilirubin Hearing Loss Sensorineural Wave form chemistry.chemical_compound Neonatal Screening Evoked Potentials Auditory Brain Stem Reaction Time medicine Humans Plasma Exchange business.industry Infant Newborn Jaundice Auditory evoked responses medicine.disease Audiometry Evoked Response Jaundice Neonatal chemistry Anesthesia Pediatrics Perinatology and Child Health Kernicterus Female Bilirubin levels medicine.symptom business After treatment Brain Stem |
Zdroj: | The Indian Journal of Pediatrics. 60:409-413 |
ISSN: | 0973-7693 0019-5456 |
DOI: | 10.1007/bf02751203 |
Popis: | Auditory evoked responses using BERA were studied in 30 newborn babies with plasma bilirubinor = 15 mgm/dl and repeated after treatment of neonatal jaundice with bilirubin levels ofor = 10 mgm/dl. A few jaundiced babies (16.5%) showed absent BERA response at the initial/subsequent examination. After treatment, 3/30 babies showed absent wave form responses and 2 of these were clinically kernicteric. Jaundiced babies had prolonged wave peak latencies and inter peak latencies. Treated babies showed a tendency towards recovery in their BERA responses which were however not complete. Total plasma bilirubin value at the time of BERA examination and mean maximal bilirubin values had no correlation with the incidence and degree of BERA abnormalities. |
Databáze: | OpenAIRE |
Externí odkaz: |