Tissue reaction to prosthetic obturator materials

Autor: Keith Kent, Uma Roa, Wayne A. Beecroft
Rok vydání: 1982
Předmět:
Zdroj: Journal of Surgical Oncology. 19:176-187
ISSN: 1096-9098
0022-4790
DOI: 10.1002/jso.2930190313
Popis: Two materials are currently used for construction of obturators to restore function when major maxillary defects are present: poly(methyl methacrylate) and poly(dimethyl siloxane). The advantages and disadvantages of the materials are examined and the physiologic response of the involved tissues is studied. Palatectomies were performed on primates and poly-(methyl methacrylate) and poly(dimethyl siloxane) obturators were placed contacting antral and nasal mucosa. Serial biopsies and clinical evaluations revealed comparable histologic responses to both materials. Poly(dimethyl siloxane) exhibited a more favorable clinical tissue response than poly(methyl methacrylate).
Databáze: OpenAIRE