Effect of the Ultrasonic Bone Scalpel on Blood Loss During Pediatric Spinal Deformity Correction Surgery
Autor: | Phillip Glivar, Scott C. Nelson, Sean Wahlquist |
---|---|
Rok vydání: | 2019 |
Předmět: |
medicine.medical_specialty
Adolescent Ultrasonic Therapy medicine.medical_treatment Blood Loss Surgical 03 medical and health sciences 0302 clinical medicine Blood loss medicine Humans Orthopedics and Sports Medicine Child Reduction (orthopedic surgery) 030222 orthopedics Neuromuscular scoliosis business.industry Medical record Retrospective cohort study Surgery Spinal Fusion medicine.anatomical_structure Scoliosis Orthopedic surgery business 030217 neurology & neurosurgery Vertebral column Cohort study |
Zdroj: | Spine Deformity. 7:582-587 |
ISSN: | 2212-134X |
Popis: | Study Design Retrospective cohort. Objective Determine the effect of the ultrasonic bone scalpel (UBS) on intraoperative blood loss and surgical time. Summary of Background Data The UBS has shown beneficial effects in limiting blood loss in spinal surgery, but no study has examined its effect in patients with neuromuscular scoliosis. Methods Clinical records were reviewed for patients aged 9–18 who underwent posterior spinal fusion surgery of five or more levels for scoliosis correction by the senior author from April 2013 until October 2016. Exclusion criteria included: vertebral column resections, previous spinal surgery, cell saver usage, cases complicated by signal loss on monitoring, and incomplete medical records. A total of 84 patients met the criteria and were included in data analysis. The UBS was routinely used for performing osteotomies and facetectomies for all cases operated after March 2015. These cases were compared to a control group who underwent surgery prior to this date in which the UBS was not used. The experimental and control groups were further divided into adolescent idiopathic (AIS) and neuromuscular (NMS) subgroups. Results EBL in AIS patients decreased from 1,211 mL in the control group to 771 mL in the UBS group for an average total reduction of 440 mL (95% CI 106, 774, p = .01). In NMS patients, EBL fell from 2,171 mL in controls to 1228 mL in the study group for an average total reduction of 943 mL (95% CI 288, 1598, p Conclusions The ultrasonic bone scalpel is effective in reducing blood loss in AIS and NMS deformity correction surgery. Surgical time is not adversely affected by its use. Level of Evidence Level II, cohort study. |
Databáze: | OpenAIRE |
Externí odkaz: |