Simplified Method for Local Correction of System International Normalized Ratio

Autor: Vani Chandrashekar
Rok vydání: 2017
Předmět:
Zdroj: Laboratory medicine. 48(3)
ISSN: 1943-7730
Popis: Background International normalized ratio (INR) derivation is dependent on the international sensitivity index (ISI) of thromboplastin. It varies with instrument and reagents used. Objective To evaluate the role of a correction factor in the derivation of INR. Methods We studied prothrombin time (PT) and INR from patients using 3 thromboplastins of varying ISI values. The correction factor was applied to the observed INR to obtain a corrected INR. Results The difference between corrected INR and observed INR values varies from -0.8 through 0.96. Conclusions Corrected INR is dependent on PT only. It can be applied to all patients irrespective of cause for elevated PT.
Databáze: OpenAIRE