The effect of varying spatial resolution on the detectability of diffuse pulmonary nodules. Assessment with digitized conventional radiographs
Autor: | D Schleuter, Frank A. DiBianca, G S Keyes, Thomas L. Lawson, W D Foley, Gerard T. Scanlon, Charles R. Wilson |
---|---|
Rok vydání: | 1981 |
Předmět: |
Solitary pulmonary nodule
medicine.medical_specialty Lung Neoplasms Receiver operating characteristic business.industry Tuberculosis Miliary Radiography Significant difference Solitary Pulmonary Nodule Conventional radiographs medicine.disease Diagnosis Differential Radiographic Image Enhancement Observer performance medicine Humans Radiology Nuclear Medicine and imaging False Positive Reactions Radiology business Image resolution Technology Radiologic |
Zdroj: | Radiology. 141(1) |
ISSN: | 0033-8419 |
Popis: | Detection and discrimination of miliary disease and small pulmonary nodules were tested at six levels of spatial resolution varying between 0.3 and 2.5 l.p./mm, and receiver operating characteristic (ROC) curves were generated. The test images were obtained by digitizing selected normal and abnormal standard film/screen radiographs. Although there was no statistically significant difference in observer performance between 0.5 and 2.5 l.p./mm, the findings may have clinical relevance. Further observer detection studies of different disease processes are planned to help formulate performance standards for an electric digital radiographic device for chest imaging. |