A modified fiber-reinforced plastics concrete interface bond-slip law for shear-strengthened RC elements under cyclic loading
Autor: | Efe Selman, Ninel Alver |
---|---|
Přispěvatelé: | Selman, Efe, Izmir Institute of Technology. Civil Engineering |
Rok vydání: | 2015 |
Předmět: |
Concrete beams
Materials science Polymers and Plastics Interface bond Concrete girders 0211 other engineering and technologies 02 engineering and technology Slip (materials science) 021105 building & construction Concretes Materials Chemistry Cyclic loading Cyclic loads Composite material Bond degradation General Chemistry Fibre-reinforced plastic 021001 nanoscience & nanotechnology Reinforced concrete Fiber reinforced plastics Reinforced plastics Shear (geology) Law Ceramics and Composites 0210 nano-technology |
Zdroj: | Polymer Composites. 37:3373-3383 |
ISSN: | 0272-8397 |
DOI: | 10.1002/pc.23535 |
Popis: | The objective of this article is to realistically analyze fiber-reinforced plastics (FRP) retrofitted reinforced concrete structures under cyclic loading taking into account FRP–concrete bond-slip law with cyclic bond degradation. In literature, even though numerous studies have been conducted in FRP–concrete interface bond-slip modeling under cyclic loads, a small number of them consider the influence of cyclic degradation on FRP–concrete interface bond behavior. Within this framework, the bond-slip law for carbon fiber-reinforced plastics–concrete interface is revised by utilizing Harajli's and Ko-Sato's approaches. The procedure is distinct from others because it develops existing deficiencies of these approaches, whereas a more reliable modeling process is proposed for use in practice. Conventional bond-slip law of Lu et al. is compared with this interface relationship stated in this investigation and the difference is clearly shown in terms of structural parameters. Experimental tests are conducted at the same time for verification. It is proved that cyclic bond degradation affects the interface behavior; thus, the structural response cannot be omitted in structural evaluations. Structural performance measures are obtained in good agreement for each level of cycles. The technique proposed clearly exhibits structural response difference between monotonic and cyclic loadings while good agreement is reached with experimental results. POLYM. COMPOS., 37:3373–3383, 2016. © 2015 Society of Plastics Engineers. Scientific and Technological Research Council of Turkey (111M559) |
Databáze: | OpenAIRE |
Externí odkaz: |