Assessment of inferior vena cava diameter by echocardiography in normal Indian population: A prospective observational study
Autor: | Beeresha Puttegowda, Natraj Shetty, Santosh Jadhav, Shivanand Patil, Jayashree Kharge, Manjunath Nanjappa Cholenahally, Rangraj Ramalingam |
---|---|
Jazyk: | angličtina |
Předmět: |
Adult
Male Original article medicine.medical_specialty Future studies RD1-811 India Vena Cava Inferior 030204 cardiovascular system & hematology Inferior vena cava 03 medical and health sciences 0302 clinical medicine Reference Values medicine Intravascular volume status Humans Diseases of the circulatory (Cardiovascular) system Prospective Studies Expiration Prospective cohort study Body mass index Inspiration business.industry Indian population 030208 emergency & critical care medicine Organ Size medicine.vein Echocardiography RC666-701 cardiovascular system Female Observational study Surgery Radiology business Cardiology and Cardiovascular Medicine |
Zdroj: | Indian Heart Journal, Vol 68, Iss S3, Pp S26-S30 (2016) |
ISSN: | 0019-4832 |
DOI: | 10.1016/j.ihj.2016.06.009 |
Popis: | Background The assessment of the IVC diameter is self explanatory for evaluation of the individuals’ volume status. Studies regarding IVC diameter estimation in normal individuals are scarce. Aim The present study aimed to define normal criteria of size and dynamics of the inferior vena cava (IVC) by M-mode echocardiography in normal individuals. Methods This was a prospective, single-center, observational study carried out at Sri Jayadeva Institute of Cardiovascular Sciences and Research between December 2011 and April 2014. A total of 4126 consecutive individuals were enrolled. Normal IVC diameter was measured both during inspiration and expiration by M-mode echocardiography in subcostal view. Results The IVC diameter varied from 0.46 to 2.26 cm in the study individuals. The IVC diameter ranged from 0.97 to 2.26 cm during expiration and from 0.46 to 1.54 cm during inspiration. A strong correlation was observed between IVC diameter and height, weight and BMI of the individuals, calculated using Pearson correlation. The correlation coefficients for expiratory and inspiratory IVC diameters as a function of BMI were 0.686 and 0.7, respectively. Conclusions Our findings corroborate the correlations between height, weight and BMI with IVC diameter. Future studies could be focused to bring about a steadfast formula for calculating IVC diameter based on demographic parameters of an individual. |
Databáze: | OpenAIRE |
Externí odkaz: |