An audit of using the H Pipelle for endometrial sampling at outpatient hysteroscopy and literature review comparison with the Pipelle de Cornier
Autor: | Gabor Halmos, Dimitrios Papoutsis, Adam Magos, Mohsen Moustafa, Maria Diletta Dacco, Dimitrios Georgantzis |
---|---|
Rok vydání: | 2012 |
Předmět: |
Adult
Gynecology medicine.medical_specialty medicine.diagnostic_test business.industry Biopsy Diagnostic hysteroscopy Endometrial sampling Obstetrics and Gynecology Hysteroscopy Middle Aged Biopsy instruments Endometrium Premenopause Reproductive Medicine Histological diagnosis Humans Medicine Female business Retrospective Studies Outpatient hysteroscopy Endometrial biopsy |
Zdroj: | European Journal of Obstetrics & Gynecology and Reproductive Biology. 165:299-301 |
ISSN: | 0301-2115 |
DOI: | 10.1016/j.ejogrb.2012.07.021 |
Popis: | A B S T R A C T Objective: To analyse the efficiency of the H Pipelle endometrial sampler at ‘‘no touch’’ (vaginoscopic) diagnostic hysteroscopy in terms of biopsy adequacy for histological diagnosis. Study design: Retrospective descriptive study of 200 premenopausal women including comparison with previously published data on traditional biopsy instruments. Results: Biopsy was adequate in 82% of cases overall, rising to 87% in those without submucous fibroids or polyps. Comparison with published data on other biopsy instruments shows that the H Pipelle is at least as efficient. Conclusion: The H Pipelle appears to be at least as effective as traditional endometrial samplers even after hysteroscopy but allows hysteroscopy and biopsy to be done using a purely ‘‘no touch’’ (vaginoscopic) technique. |
Databáze: | OpenAIRE |
Externí odkaz: |