Ultrasound and Microbubbles Enhance Uptake of Doxorubicin in Murine Kidneys
Autor: | Sabine Leh, Odd Helge Gilja, Mireia Mayoral Safont, Oddrun Anita Gudbrandsen, Øystein Solberg Eikrem, Bettina Riedel, Mihaela-Lucia Popa, Lea Landolt, Janka Bábíčková, Spiros Kotopoulis, Jan Schjøtt, Kjell Ove Fossan, Emmet McCormack, Hans-Peter Marti |
---|---|
Rok vydání: | 2021 |
Předmět: |
medicine.medical_specialty
kidney mice Urology Pharmaceutical Science doxorubicin Article microbubbles Pharmacy and materia medica medicine Doxorubicin sonoporation ultrasound Kidney business.industry Ultrasound Histology RS1-441 medicine.anatomical_structure Drug delivery Microbubbles business Sonoporation After treatment medicine.drug |
Zdroj: | Pharmaceutics Pharmaceutics; Volume 13; Issue 12; Pages: 2038 Pharmaceutics, Vol 13, Iss 2038, p 2038 (2021) |
ISSN: | 1999-4923 |
Popis: | The use of ultrasound and microbubble-enhanced drug delivery, commonly referred to as sonoporation, has reached numerous clinical trials and has shown favourable results. Nevertheless, the microbubbles and acoustic path also pass through healthy tissues. To date, the majority of studies have focused on the impact to diseased tissues and rarely evaluated the impact on healthy and collateral tissue. The aim of this study was to test the effect and feasibility of low-intensity sonoporation on healthy kidneys in a mouse model. In our work here, we used a clinical diagnostic ultrasound system (GE Vivid E9) with a C1-5 ultrasound transducer combined with a software modification for 20-µs-long pulses to induce the ultrasound-guided drug delivery of doxorubicin (DOX) in mice kidneys in combination with SonoVue® and Sonazoid™ microbubbles. The acoustic output settings were within the commonly used diagnostic ranges. Sonoporation with SonoVue® resulted in a significant decrease in weight vs. DOX alone (p = 0.0004) in the first nine days, whilst all other comparisons were not significant. Ultrasound alone resulted in a 381% increase in DOX uptake vs. DOX alone (p = 0.0004), whilst SonoVue® (p = 0.0001) and Sonazoid™ (p < 0.0001) further increased the uptake nine days after treatment (419% and 493%, respectively). No long-standing damage was observed in the kidneys via histology. In future sonoporation and drug uptake studies, we therefore suggest including an “ultrasound alone” group to verify the actual contribution of the individual components of the procedure on the drug uptake and to perform collateral damage studies to ensure there is no negative impact of low-intensity sonoporation on healthy tissues. |
Databáze: | OpenAIRE |