Traceability and Characterization of a 1000 kV HVDC Reference Divider
Autor: | Tatu Nieminen, Mohammad Kharezy, A. P. Elg, Anders Bergman, Jari Hällström |
---|---|
Rok vydání: | 2015 |
Předmět: |
measurement standards
Traceability Computer science high-voltage techniques Voltage regulator law.invention Dropout voltage law Calibration Electronic engineering Electrical and Electronic Engineering uncertainty Instrumentation Physics Resistive touchscreen business.industry Voltage divider Electrical engineering Characterization (materials science) voltage dividers High-voltage dc (HVDC) transmission Measurement uncertainty Voltage regulation Resistor business Voltage |
Zdroj: | Elg, A-P, Bergman, A, Hällström, J, Kharezy, M & Nieminen, T 2015, ' Traceability and Characterization of a 1000 kV HVDC Reference Divider ', IEEE Transactions on Instrumentation and Measurement, vol. 64, no. 6, pp. 1709-1715 . https://doi.org/10.1109/TIM.2015.2410373 |
ISSN: | 1557-9662 0018-9456 |
Popis: | This paper presents the characterization of a resistive high-voltage dc (HVDC) reference divider and methods to establish traceability. The divider is designed for use as a laboratory reference for calibration of HVDC measuring systems up to 1000 kV. Targeting a measurement uncertainty of 20 $\mu \text{V}$ /V at full voltage has put a focus on the temperature coefficients of the resistors, elimination of humidity dependence, and control of leakage currents in the high-voltage arm. A scale factor calibration against a 50 kV divider at 10 kV leads to an expanded uncertainty of 15 $\mu \text{V}$ /V. |
Databáze: | OpenAIRE |
Externí odkaz: |