Stability Assessment of Current Controller with Harmonic Compensator for LCL-Filtered Grid-Connected Inverter under Distorted Weak Grid

Autor: Thuy Vi Tran, Kyeong-Hwa Kim, Seung-Jin Yoon
Jazyk: angličtina
Rok vydání: 2020
Předmět:
Computer science
020209 energy
02 engineering and technology
lcsh:Technology
Stability assessment
Radio spectrum
law.invention
stability assessment
lcsh:Chemistry
Robustness (computer science)
law
Control theory
0202 electrical engineering
electronic engineering
information engineering

LCL filter
General Materials Science
grid-connected inverter
Instrumentation
lcsh:QH301-705.5
Digital signal processing
Fluid Flow and Transfer Processes
business.industry
lcsh:T
Process Chemistry and Technology
020208 electrical & electronic engineering
Direct current
General Engineering
Grid
grid impedance variation
lcsh:QC1-999
Computer Science Applications
Capacitor
lcsh:Biology (General)
lcsh:QD1-999
lcsh:TA1-2040
harmonic compensator
Inverter
distorted weak grid
business
lcsh:Engineering (General). Civil engineering (General)
lcsh:Physics
Zdroj: Applied Sciences
Volume 11
Issue 1
Applied Sciences, Vol 11, Iss 212, p 212 (2021)
ISSN: 2076-3417
DOI: 10.3390/app11010212
Popis: An assessment of the stability and performance of current controllers with harmonic compensators is presented for an inductive-capacitive-inductive (LCL)-filtered grid-connected inverter under distorted weak grid conditions. By using two typical current control schemes which are the direct current controller with the capacitor current-based active damping and integral-resonant state feedback current controller, the closed-loop system stability and current control performance are investigated in the presence of both uncertain grid impedance and distorted grid. Even though the controller stability has been investigated under weak grid in several studies, the stability assessment of the entire current control scheme, including the harmonic resonant controllers, still needs a further comprehensive investigation. The system stability is analyzed by obtaining the movement of the closed-loop poles in the discrete-time domain when the grid impedance varies. To fully study the impact of distorted weak grid condition on the LCL filters, three LCL filter parameter sets giving the resonance frequency in different frequency bands are chosen for the purpose of evaluating the system robustness and grid-injected current quality. In order to support the presented theoretical analyses, comprehensive simulation and experimental results based on 32-bit DSP TMS320F28335 to control 2 kVA grid-connected inverter are presented in terms of grid current quality and control stability in the environment of both uncertain grid impedance and distorted grid.
Databáze: OpenAIRE