Detection limits of the NaI(Tl) shielded HPGe spectrometer
Autor: | Ivan Anicin, Istvan Bikit, Miodrag Krmar, N Žikić, Miroslav Veskovic, Ž Đurčić, Lj. Čonkić, Jaroslav Slivka |
---|---|
Rok vydání: | 1999 |
Předmět: |
Physics
Detection limit Nuclear and High Energy Physics Spectrometer Physics::Instrumentation and Detectors 010308 nuclear & particles physics business.industry low-level spectroscopy 010403 inorganic & nuclear chemistry 01 natural sciences 0104 chemical sciences Semiconductor detector law.invention Optics Nuclear magnetic resonance law NaI(Tl) shield Shield 0103 physical sciences Shielded cable Nuclear Experiment business Spectroscopy Hpge detector Instrumentation |
Zdroj: | Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment |
ISSN: | 0168-9002 |
DOI: | 10.1016/s0168-9002(98)01258-3 |
Popis: | The results of a detailed study of the low-level performance of a NaI(Tl) shield added to an iron shielded HPGe spectrometer are presented. Both the slow and the fast anticoincidence gating modes were tested, the slow mode being found better suited for general low-level spectroscopy applications. In long runs the stability of the system in this mode is satisfactory. The anticoincidence action of the NaI(Tl) shield lowers the integral background of the iron shielded HPGe detector in the energy range from 30 keV to 2 MeV by a factor of 6.5, and suppresses the continuum above 150 keV by a factor larger than 10. (C) 1999 Elsevier Science B.V. All rights reserved. |
Databáze: | OpenAIRE |
Externí odkaz: |