Anastomosis of bypass grafts using a low-powered CO2 laser

Autor: R Zirl, O.H. Frazier, M I Bossart, Nakatani T, S A Shehab, Branislav Radovancevic, Steven M. Parnis
Rok vydání: 1989
Předmět:
Zdroj: Lasers in Surgery and Medicine. 9:30-36
ISSN: 1096-9101
0196-8092
DOI: 10.1002/lsm.1900090107
Popis: The purpose of this study was to evaluate the feasibility of using a low-powered CO2 laser to perform end-to-side anastomoses of bypass grafts. The internal jugular veins of 13 domestic swine were removed and used as grafts to bypass their ligated carotid arteries. Each end of the vein graft was apposed to the artery with four to six temporary stay sutures, and a waveguide delivery CO2 laser with a power density of 900 mW/mm2 was used to perform the anastomoses, after which the sutures were removed. The animals were sacrificed postoperatively at five time intervals: 2 to 4 hours, 5 days, 1 month, 3 months, and 5 months. Of the 10 anastomoses studied at 2 to 4 hours, 70% were fully patent, none thrombosed, and 30% disrupted. Of the 16 anastomoses studied between 5 days and 5 months postoperatively, 88% were patent, 12% thrombosed, and none disrupted. None of the animals developed aneurysms at any stage of this investigation. Histologic analysis of acute studies revealed thermal damage such as charring of tissue, unraveling of the collagen fibrils, and the formation of microvacuoles. Within 3 months, the anastomotic sites showed localized healing with intimal fibromuscular proliferation and dense fibrous tissue. Good apposition of tissue was found to be of great importance in achieving patency of vessels in this procedure.
Databáze: OpenAIRE