Reproducibility of the AO/ASIF and Gartland classifications for supracondylar fractures of the humerus in children
Autor: | Carlos Fontoura Filho, Murilo Antônio Rocha, Igor Tadeu Silveira Rocha, André de Siqueira Faria |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2015 |
Předmět: |
Reproducibility of results
medicine.medical_specialty Radiography Concordance medicine.medical_treatment Fraturas do úmero lcsh:Medicine Criança lcsh:Orthopedic surgery medicine Observer-dependent variations Internal fixation Humerus Statistical analysis Reprodutibilidade dos resultados Children Orthodontics Fractures of the humerus Reproducibility Osteosynthesis business.industry lcsh:R General Medicine Gartland classification Surgery Variações dependentes do observador lcsh:RD701-811 Fraturas do úmero/classificação medicine.anatomical_structure Original Article Fractures of the humerus/classification business |
Zdroj: | Revista Brasileira de Ortopedia, Volume: 50, Issue: 3, Pages: 266-269, Published: JUN 2015 Revista Brasileira de Ortopedia v.50 n.3 2015 Revista Brasileira de Ortopedia Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) instacron:SBOT Revista Brasileira de Ortopedia, Vol 50, Iss 3, Pp 266-269 (2015) |
Popis: | OBJECTIVE: To evaluate the reproducibility of the radiographic classifications of Gartland and the Association for Osteosynthesis/Association for the Study of Internal Fixation (AO/ASIF) for supracondylar fractures of the humerus in children.METHODS: On two occasions, 50 radiographs in anteroposterior and lateral views were evaluated by three pediatric orthopedists in accordance with the Gartland and AO/ASIF pediatric classifications. Their responses were subjected to statistical analysis consisting of calculation of the κ coefficient to assess the intra- and interobserver concordance, in both classifications.RESULTS: The strength of the intraobserver concordance was high or near perfect for the three examiners in the two classification systems. The strength of the interobserver concordance was high in the two systems, with κcoefficients of 0.756 for the Gartland classification and 0.766 for the AO/ASIF classification.CONCLUSION: The Gartland and AO/ASIF classification systems showed similar reproducibility and performance. High strength of concordance was seen in the intra- and interobserver analyses. OBJETIVO: Avaliar a reprodutibilidade das classificações radiográficas de Gartland e Association for Osteosynthesis/Association for the Study of Internal Fixation (AO/ASIF) para fraturas supracondilianas de úmero em crianças.MÉTODOS: Em duas ocasiões foram avaliadas por três cirurgiões ortopedistas pediátricos 50 radiografias nas incidências anteroposteriores e perfil de acordo com as classificações de Gartland e AO/ASIF pediátrica. As respostas foram submetidas à análise estatística pelo cálculo do coeficiente κ para avaliar a concordância intra- e interobservador, em ambas as classificações.RESULTADOS: A força de concordância intraobservador foi grande ou quase perfeita para os três examinadores nos dois sistemas de classificação. A força de concordância interobservador foi grande nos dois sistemas, com coeficiente κ de 0,756 para classificação de Gartland e de 0,766 para classificação AO/ASIF.CONCLUSÃO: Os sistemas de classificação de Gartland e AO/ASIF mostraram reprodutibilidade e desempenho similar. Observou-se grande força de concordância nas análises intra- e interobservador. |
Databáze: | OpenAIRE |