Psychometric properties of the MOBITEC-GP mobile application for real-life mobility assessment in older adults

Autor: Eleftheria Giannouli, Eun-Kyeong Kim, Cheng Fu, Robert Weibel, Alexandros Sofios, Denis Infanger, Erja Portegijs, Taina Rantanen, Haosheng Huang, Arno Schmidt-Trucksäss, Andreas Zeller, Roland Rössler, Timo Hinrichs
Přispěvatelé: University of Zurich, Giannouli, Eleftheria, SMART Movements (SMART)
Rok vydání: 2022
Předmět:
Zdroj: Geriatric Nursing, 48
Geriatric Nursing, 48, 273-279. MOSBY-ELSEVIER
GERIATRIC NURSING
ISSN: 0197-4572
1528-3984
DOI: 10.5167/uzh-223551
Popis: Aim of this study was to test the reliability and validity of the life-space measures and walking speed delivered by the MOBITEC-GP app. Participants underwent several supervised walking speed assessments as well as a 1-week life-space assessment during two assessment sessions 9 days apart. Fifty-seven older adults (47.4% male, mean age= 75.3 (±5.9) years) were included in the study. The MOBITEC-GP app showed moderate to excellent test-retest reliability (ICCs between 0.584 and 0.920) and validity (ICCs between 0.468 and 0.950) of walking speed measurements of 50 meters and above and of most 1-week life-space parameters, including life-space area, time spent out-of-home, and action range. The MOBITEC-GP app for Android is a reliable and valid tool for the assessment of real-life walking speed (at distances of 50 metres and above) and life-space parameters of older adults. Future studies should look into technical issues more systematically in order to avoid invalid measurements.
Geriatric Nursing, 48
Databáze: OpenAIRE