Use of optimised MLP neural networks for spatiotemporal estimation of indoor environmental conditions of existing buildings
Autor: | Ana Ogando-Martínez, Francisco Troncoso-Pastoriza, Lara Febrero-Garrido, Javier López-Gómez, Enrique Granada-Álvarez, Miguel Martínez-Comesaña |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
Estimation
Environmental Engineering Artificial neural network Computer science Geography Planning and Development Real-time computing Context (language use) Building and Construction Perceptron 3305.32 Ingeniería de Estructuras 3305.90 Transmisión de Calor en la Edificación Research centre 3305 Tecnología de la Construcción Genetic algorithm Environmental quality Civil and Structural Engineering Interpolation |
Zdroj: | Investigo. Repositorio Institucional de la Universidade de Vigo Universidade de Vigo (UVigo) |
Popis: | Financiado para publicación en acceso aberto: Universidade de Vigo/CISUG Controlling the indoor environmental quality in real time is essential for the health, well-being and productivity of occupants of a building. In recent years, research has focused on improving monitoring devices and strategies and developing techniques for estimating indoor conditions. The use of machine learning algorithms in this context has increased considerably. However, monitoring data in real time from large multizone working areas is challenging. The aim of this work is to provide an interpolation methodology based on the use of optimised multilayered perceptron neural networks to estimate the indoor environmental conditions of a building in real time. These estimations are obtained without the need for neither monitoring in the occupied working area nor human intervention and considering low-cost sensors. The neural network is optimised by implementing the multiobjective genetic algorithm NSGA-II to find the best architecture in terms of error and complexity. This method was applied to the building of a research centre in north-western Spain, where interpolated values for indoor air temperature, relative humidity and CO concentration were obtained. The results of this case study yielded relative errors close to 6% for temperature, 5% for relative humidity, and 12% for CO concentration. These values validate the methodology developed for the estimation of indoor environmental conditions and the contribution of this research to the improvement of the monitoring and control of the indoor environmental quality of a building. Agencia Estatal de Investigación | Ref. RTI2018-096296-B-C2 Ministerio de Ciencia, Innovación y Universidades | Ref. FPU17/01834 Ministerio de Ciencia, Innovación y Universidades | Ref. FPU19/01187 |
Databáze: | OpenAIRE |
Externí odkaz: |