Cardiac output estimation by multi-beat analysis of the radial arterial blood pressure waveform versus intermittent pulmonary artery thermodilution: a method comparison study in patients treated in the intensive care unit after off-pump coronary artery bypass surgery

Autor: Alexander Hapfelmeier, Mathias Kubik, Bernd Saugel, Stefano Romagnoli, Valerie Peters, Gillis Greiwe
Rok vydání: 2019
Předmět:
Adult
Male
Cardiac output
medicine.medical_specialty
Critical Care
medicine.medical_treatment
Thermodilution
Coronary Artery Bypass
Off-Pump

Hemodynamics
Blood Pressure
Health Informatics
Pulmonary Artery
Critical Care and Intensive Care Medicine
03 medical and health sciences
Coronary artery bypass surgery
0302 clinical medicine
030202 anesthesiology
medicine.artery
Internal medicine
medicine
Humans
Arterial Pressure
Prospective Studies
Cardiac Output
Original Research
Aged
Monitoring
Physiologic

Off-pump coronary artery bypass
business.industry
Pulmonary artery catheter
030208 emergency & critical care medicine
Middle Aged
Arterial catheter
Intensive Care Units
Anesthesiology and Pain Medicine
Blood pressure
Catheterization
Swan-Ganz

Radial Artery
Pulmonary artery
Cardiology
Female
business
Zdroj: J Clin Monit Comput
ISSN: 1573-2614
1387-1307
Popis: Cardiac output (CO) is a key hemodynamic variable that can be minimally invasively estimated by pulse wave analysis. Multi-beat analysis is a novel pulse wave analysis method. In this prospective observational clinical method comparison study, we compared CO estimations by multi-beat analysis with CO measured by intermittent pulmonary artery thermodilution (PATD) in adult patients treated in the intensive care unit (ICU) after off-pump coronary artery bypass surgery (OPCAB). We included patients after planned admission to the ICU after elective OPCAB who were monitored with a radial arterial catheter and a pulmonary artery catheter. At seven time points, we determined CO using intermittent PATD (PATD-CO; reference method) and simultaneously recorded the radial arterial blood pressure waveform that we later used to estimate CO using multi-beat analysis (MBA-CO; test method) with the Argos monitor (Retia Medical; Valhalla, NY, USA). Blood pressure waveforms impaired by inappropriate damping properties or artifacts were excluded. We compared PATD-CO and MBA-CO using Bland–Altman analysis accounting for repeated measurements, the percentage error, and the concordance rate derived from four-quadrant plot analysis (15% exclusion zone). We analyzed 167 CO values of 31 patients. Mean PATD-CO was 5.30 ± 1.22 L/min and mean MBA-CO was 5.55 ± 1.82 L/min. The mean of the differences between PATD-CO and MBA-CO was 0.08 ± 1.10 L/min (95% limits of agreement: − 2.13 L/min to + 2.29 L/min). The percentage error was 40.7%. The four-quadrant plot-derived concordance rate was 88%. CO estimation by multi-beat analysis of the radial arterial blood pressure waveform (Argos monitor) shows reasonable agreement compared with CO measured by intermittent PATD in adult patients treated in the ICU after OPCAB.
Databáze: OpenAIRE