Cardiac output estimation by multi-beat analysis of the radial arterial blood pressure waveform versus intermittent pulmonary artery thermodilution: a method comparison study in patients treated in the intensive care unit after off-pump coronary artery bypass surgery
Autor: | Alexander Hapfelmeier, Mathias Kubik, Bernd Saugel, Stefano Romagnoli, Valerie Peters, Gillis Greiwe |
---|---|
Rok vydání: | 2019 |
Předmět: |
Adult
Male Cardiac output medicine.medical_specialty Critical Care medicine.medical_treatment Thermodilution Coronary Artery Bypass Off-Pump Hemodynamics Blood Pressure Health Informatics Pulmonary Artery Critical Care and Intensive Care Medicine 03 medical and health sciences Coronary artery bypass surgery 0302 clinical medicine 030202 anesthesiology medicine.artery Internal medicine medicine Humans Arterial Pressure Prospective Studies Cardiac Output Original Research Aged Monitoring Physiologic Off-pump coronary artery bypass business.industry Pulmonary artery catheter 030208 emergency & critical care medicine Middle Aged Arterial catheter Intensive Care Units Anesthesiology and Pain Medicine Blood pressure Catheterization Swan-Ganz Radial Artery Pulmonary artery Cardiology Female business |
Zdroj: | J Clin Monit Comput |
ISSN: | 1573-2614 1387-1307 |
Popis: | Cardiac output (CO) is a key hemodynamic variable that can be minimally invasively estimated by pulse wave analysis. Multi-beat analysis is a novel pulse wave analysis method. In this prospective observational clinical method comparison study, we compared CO estimations by multi-beat analysis with CO measured by intermittent pulmonary artery thermodilution (PATD) in adult patients treated in the intensive care unit (ICU) after off-pump coronary artery bypass surgery (OPCAB). We included patients after planned admission to the ICU after elective OPCAB who were monitored with a radial arterial catheter and a pulmonary artery catheter. At seven time points, we determined CO using intermittent PATD (PATD-CO; reference method) and simultaneously recorded the radial arterial blood pressure waveform that we later used to estimate CO using multi-beat analysis (MBA-CO; test method) with the Argos monitor (Retia Medical; Valhalla, NY, USA). Blood pressure waveforms impaired by inappropriate damping properties or artifacts were excluded. We compared PATD-CO and MBA-CO using Bland–Altman analysis accounting for repeated measurements, the percentage error, and the concordance rate derived from four-quadrant plot analysis (15% exclusion zone). We analyzed 167 CO values of 31 patients. Mean PATD-CO was 5.30 ± 1.22 L/min and mean MBA-CO was 5.55 ± 1.82 L/min. The mean of the differences between PATD-CO and MBA-CO was 0.08 ± 1.10 L/min (95% limits of agreement: − 2.13 L/min to + 2.29 L/min). The percentage error was 40.7%. The four-quadrant plot-derived concordance rate was 88%. CO estimation by multi-beat analysis of the radial arterial blood pressure waveform (Argos monitor) shows reasonable agreement compared with CO measured by intermittent PATD in adult patients treated in the ICU after OPCAB. |
Databáze: | OpenAIRE |
Externí odkaz: |