Reliability and precision of 3D wireless measurement of scapular kinematics
Autor: | Suzanne H. Wiertsema, Joost Dekker, Josien C. van den Noort, Jaap Harlaar, Casper P. Schönhuth, Karin M. C. Hekman |
---|---|
Přispěvatelé: | Radiology and Nuclear Medicine, AMS - Musculoskeletal Health, AMS - Rehabilitation & Development, Rehabilitation medicine, Orthopedic Surgery and Sports Medicine, Psychiatry, EMGO - Musculoskeletal health, MOVE Research Institute, EMGO+ - Musculoskeletal Health, Research Institute MOVE |
Rok vydání: | 2014 |
Předmět: |
Adult
Male musculoskeletal diseases Shoulder Upper extremity Intraclass correlation Biomedical Engineering Kinematics Scapula medicine Humans Inertial sensing Biomechanics Humerus Range of Motion Articular Orthodontics business.industry Wireless measurement Reproducibility of Results Anatomy Middle Aged Reliability musculoskeletal system Telemedicine Biomechanical Phenomena Computer Science Applications medicine.anatomical_structure Joint Scapular kinematics Female Range of motion business Wireless Technology |
Zdroj: | Medical and Biological Engineering and Computing, 52(11), 921-931. Springer Verlag Medical & Biological Engineering & Computing, 52(11), 921-931. Springer Verlag van den Noort, J C, Wiertsema, S H, Hekman, K M, Schonhuth, C P, Dekker, J & Harlaar, J 2014, ' Reliability and precision of 3D wireless measurement of scapular kinematics ', Medical & Biological Engineering & Computing, vol. 52, no. 11, pp. 921-931 . https://doi.org/10.1007/s11517-014-1186-2 |
ISSN: | 0140-0118 |
DOI: | 10.1007/s11517-014-1186-2 |
Popis: | To direct interventions aimed at improving scapular position and motion in shoulder pathologies, a clinically feasible, objective, sensitive and reliable assessment of scapular dyskinesis is needed. The aim of this study is to evaluate the intra- and inter-observer reliability and the precision of 3D scapula kinematics measurement using wireless sensors of an inertial and magnetic measurement system (IMMS). Scapular kinematics during humerus anteflexion and abduction of 20 subjects without shoulder pathologies were measured twice by two observers at two different days, using IMMS. Similar movement patterns and corresponding high intraclass correlation coefficients were found within (intra) and between (inter) observers, especially for scapular retraction/protraction (0.65–0.85) and medio/lateral rotation (0.56–0.91). Lowest reliability and highest difference in range of motion were observed for anterior/posterior tilt. Medio/lateral rotation and anterior/posterior tilt showed a high precision, with standard error of measurement being mostly below 5°. The inter-observer measurements of retraction/protraction showed lowest precision, reflected in systematic differences. This is caused by an offset in anatomical calibration of the sensors. IMMS enables easy and objective measurement of 3D scapula kinematics. Further research in a patient population should focus on clinical feasibility and validity for measurement of scapular dyskinesis. This would include the application of a scapula locator to enhance anatomical calibration. |
Databáze: | OpenAIRE |
Externí odkaz: |