Pneumococcal meningitis post-cochlear implantation: Preventative measures
Autor: | Stephen O'Leary, Benjamin P. C. Wei, Robert K. Shepherd, Roy M. Robins-Browne, Graeme M. Clark |
---|---|
Rok vydání: | 2010 |
Předmět: |
Pediatrics
medicine.medical_specialty Prosthesis-Related Infections medicine.medical_treatment medicine.disease_cause Pneumococcal Vaccines Drug Delivery Systems Risk Factors Cochlear implant Streptococcus pneumoniae medicine Humans Prosthesis-Related Infection Cochlear implantation Electrodes Meningitis Pneumococcal business.industry Clinical study design medicine.disease Cochlear Implantation Anti-Bacterial Agents Surgery Pneumonia Cochlear Implants Otorhinolaryngology Ear Inner Implant business Meningitis |
Zdroj: | Otolaryngology - Head and Neck Surgery. 143:S9-S14 |
ISSN: | 0194-5998 |
Popis: | OBJECTIVE: Both clinical data and laboratory studies demonstrated the risk of pneumococcal meningitis post-cochlear implantation. This review examines strategies to prevent post-implant meningitis. DATA SOURCES: Medline/PubMed database; English articles after 1980. Search terms: cochlear implants, pneumococcus meningitis, streptococcus pneumonia, immunization, prevention. REVIEW METHODS: Narrative review. All articles relating to post-implant meningitis without any restriction in study designs were assessed and information extracted. RESULTS: The presence of inner ear trauma as a result of surgical technique or cochlear implant electrode array design was associated with a higher risk of post-implant meningitis. Laboratory data demonstrated the effectiveness of pneumococcal vaccination in preventing meningitis induced via the hematogenous route of infection. Fibrous sealing around the electrode array at the cochleostomy site, and the use of antibiotic-coated electrode array reduced the risk of meningitis induced via an otogenic route. CONCLUSION: The recent scientific data support the U.S. Food and Drug Administration recommendation of pneumococcal vaccination for the prevention of meningitis in implant recipients. Nontraumatic cochlear implant design, surgical technique, and an adequate fibrous seal around the cochleostomy site further reduce the risk of meningitis. |
Databáze: | OpenAIRE |
Externí odkaz: |