Multicentre evaluation of the urine analyser Miditron Junior
Autor: | D Nagel, D Kutter, B Gambke, T Kouri, T Vukovich, A Wefers |
---|---|
Rok vydání: | 1997 |
Předmět: |
Analyte
Urobilinogen Urinalysis medicine.diagnostic_test business.industry Clinical Biochemistry Analyser Analytical chemistry Reproducibility of Results General Medicine Repeatability Urine Colorimetry (chemical method) chemistry.chemical_compound chemistry Evaluation Studies as Topic Medicine Relative density Humans Colorimetry Reagent Kits Diagnostic business |
Zdroj: | Scandinavian journal of clinical and laboratory investigation. 57(7) |
ISSN: | 0036-5513 |
Popis: | A multicentre evaluation of the urine analyser Miditron Junior was performed at four laboratories. The Miditron Junior analyser provides semi-quantitative results for erythrocytes, bilirubin, urobilinogen, ketone bodies, glucose, protein, nitrite, leukocytes, pH and relative density. Accuracy of the Miditron Junior analyser was evaluated by comparison to quantitative analytical chemistry methods (glucose, total protein), physical methods (pH, relative density), and microscopic methods (erythrocytes, leukocytes). Agreement was defined as identical or neighbouring concentration block. The level of agreement found with chemical, physical or microscopic methods for the six analytes tested varied from 79 to 99%. The within-run precision was determined as repeatability by using 31 native urines. The results of repeated measurements (n = 10) fell in the same concentration block, or in case of borderline concentration were spaced between two adjacent colour blocks. Day-to-day precision covering a minimum of 20 days using commercially available control solutions yielded results within +/- one colour block from the mean. |
Databáze: | OpenAIRE |
Externí odkaz: |