030218 nuclear medicine & medical imaging Brain Ischemia Correlation 03 medical and health sciences symbols.namesake 0302 clinical medicine Nuclear magnetic resonance Medicine Effective diffusion coefficient Animals Radiology Nuclear Medicine and imaging Magnetization transfer Ischemic Stroke medicine.diagnostic_test business.industry Brain Neoplasms Magnetic resonance imaging Amides Magnetic Resonance Imaging Pearson product-moment correlation coefficient Rats Stroke Cerebral blood flow Ischemic stroke symbols Protons business 030217 neurology & neurosurgery |
Zdroj: | Magnetic resonance in medicineREFERENCES. 85(4) |
ISSN: | 1522-2594 |
Popis: | Purpose To assess the correlation and differences between common amide proton transfer (APT) quantification methods in the diagnosis of ischemic stroke. Methods Five APT quantification methods, including asymmetry analysis and its variants as well as two Lorentzian model-based methods, were applied to data acquired from six rats that underwent middle cerebral artery occlusion scanned at 9.4T. Diffusion and perfusion-weighted images, and water relaxation time maps were also acquired to study the relationship of these conventional imaging modalities with the different APT quantification methods. Results The APT ischemic area estimates had varying sizes (Jaccard index: 0.544 ≤ J ≤ 0.971) and had varying correlations in their distributions (Pearson correlation coefficient: 0.104 ≤ r ≤ 0.995), revealing discrepancies in the quantified ischemic areas. The Lorentzian methods produced the highest contrast-to-noise ratios (CNRs; 1.427 ≤ CNR ≤ 2.002), but generated APT ischemic areas that were comparable in size to the cerebral blood flow (CBF) deficit areas; asymmetry analysis and its variants produced APT ischemic areas that were smaller than the CBF deficit areas but larger than the apparent diffusion coefficient deficit areas, though having lower CNRs (0.561 ≤ CNR ≤ 1.083). Conclusion There is a need to further investigate the accuracy and correlation of each quantification method with the pathophysiology using a larger scale multi-imaging modality and multi-time-point clinical study. Future studies should include the magnetization transfer ratio asymmetry results alongside the findings of the study to facilitate the comparison of results between different centers and also the published literature. |
Databáze: | OpenAIRE |
Externí odkaz: |