Intraocular medicine.medical_specialty Optics and Photonics Materials science genetic structures medicine.medical_treatment Reproducibility of Results Intraocular lens Diagnostic Techniques Ophthalmological eye diseases Sensory Systems law.invention Lens (optics) Cellular and Molecular Neuroscience Ophthalmology law Intraocular lens power medicine sense organs |
Zdroj: | Experimental eye research. 140 |
ISSN: | 1096-0007 |
Popis: | In this paper we describe a new method for measuring the intraocular lens (IOL) power using a focimeter, a negative ophthalmic lens and a saline solution (0.9% NaCl). To test this we measured the power of 58 different IOLs and we compared them with the power stated by the manufacturer. Despite the limitations, the results show a good correlation. |