Determination of silver in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling
Autor: | Bernhard Welz, Maria Goreti R. Vale, Fabiola Vignola, Helmut Becker-Ross, Ivan N.B. Castilho, Rennan Geovanny Oliveira Araujo, Sergio Luis Costa Ferreira, Patricia Smichowski |
---|---|
Rok vydání: | 2013 |
Předmět: |
Detection limit
Chemistry Glass fiber Analytical chemistry Silver determination Particulates Standard solution Mass spectrometry Analytical Chemistry Certified reference materials Direct solid sampling analysis Glass fiber filters Airborne particulate matter Graphite furnace atomic absorption Pyrolysis Spectroscopy HR-CS GF AAS |
Zdroj: | Repositório Institucional da UFBA Universidade Federal da Bahia (UFBA) instacron:UFBA |
ISSN: | 0026-265X |
DOI: | 10.1016/j.microc.2012.05.009 |
Popis: | p. 36–40 Submitted by Santiago Fabio (fabio.ssantiago@hotmail.com) on 2013-10-29T19:46:35Z No. of bitstreams: 1 5555555.pdf: 374813 bytes, checksum: 9e24884b818f84498479904799d6df24 (MD5) Made available in DSpace on 2013-10-29T19:46:35Z (GMT). No. of bitstreams: 1 5555555.pdf: 374813 bytes, checksum: 9e24884b818f84498479904799d6df24 (MD5) Previous issue date: 2013 The present work aims at the determination of silver in airborne particulate matter (APM) collected on glass fiber filters using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry. The secondary line at 338.289 nm was used for all measurements. A manual solid sampling accessory and solid sampling platforms were used for sample introduction. A mass of 400 μg of ruthenium was thermally deposited on the platform surface as permanent modifier. The optimum pyrolysis and atomization temperature was 1,000 and 2,000 °C, respectively. Aqueous standard solutions were used for calibration exclusively. The analytical parameters obtained for the proposed method were as follows: characteristic mass, 4.4 pg Ag; detection limit (3σ, n = 10), 17 ng g− 1; and quantification limit (10σ, n = 10), 58 ng g− 1. These limits are equivalent to 0.05 and 0.16 ng m− 3, respectively, for 0.36 mg of sample mass (filter + APM) and an average volume of 1,440 m3 air that had passed through the filter. The certified reference material urban particulate matter, NIST 1648, was used for checking the accuracy. Four filter samples with APM collected in Buenos Aires, Argentina, were analyzed. According to our study, the concentration of silver (average ± confidence interval at 95% level, n = 5) varied between 0.64 ± 0.06 and 1.18 ± 0.07 μg g− 1, corresponding to 1.99 ± 0.11 and 4.54 ± 0.26 ng m− 3. The precision, expressed as relative standard deviation, varied between 1.6 and 7.1% (n = 5). The analytical method proved to be simple, fast and reliable. Highlights ► Determination of Ag in APM sample by HR-CS SS-GFAAS was proposed. ► The proposed method is simple, fast, reliable and suitable for routine applications. ► Procedure of determination of silver in environmental samples avoiding dissolution. ► Solid sampling is environmentally friendly when compared conventional methods. Salvador |
Databáze: | OpenAIRE |