An innovative adhesive procedure for connecting transpalatal arches with palatal implants
Autor: | Thomas Bernhart, Gerhard Kucher, Hans Peter Bantleon, Adriano Giacomo Crismani |
---|---|
Rok vydání: | 2005 |
Předmět: |
Time Factors
Tooth Movement Techniques Computer science Single visit Surface Properties Dentistry Orthodontics Composite Resins Tensile Strength Ultimate tensile strength Orthodontic Wires Humans Orthodontic Appliance Design Arch Bone Wires Dental Implants business.industry Palate Dental Bonding Health Care Costs Stainless Steel Adhesive Implant Stress Mechanical Absolute stability business |
Zdroj: | European journal of orthodontics. 27(3) |
ISSN: | 0141-5387 |
Popis: | The aim of this presentation is to describe an innovative adhesive procedure for connecting palatal implants with transpalatal arches (TPAs). The steps required for completing the procedure, the costs involved and the requisite time were reviewed and compared with those of two alternative procedures reported in the literature. To establish the stability and reliability of the procedure in vitro, tensile stress tests were performed. The results were evaluated in view of a potential loss of anchorage and compared with reported data. The innovative adhesive procedure ensured a stable and precise connection between TPAs and palatal implants during a single visit in a chair-side time of 42 minutes. The costs incurred were euro 12.33. The composite-connected component parts resisted breakage up to a mean force of 3323.16 cN. Absolute stability of the TPA-palatal implant connection in terms of maximal anchorage was limited to a mean force of 408.05 cN at a wire strength of 0.036 inches. |