Dynamic range and linearity tradeoff in detectors for interferometric radiometers

Autor: M. Vall llossera, Nuria Duffo, L. Sagues, Ignasi Corbella, Adriano Camps, Francesc Torres
Přispěvatelé: Universitat Politècnica de Catalunya. Departament de Teoria del Senyal i Comunicacions, Universitat Politècnica de Catalunya. RSLAB - Grup de Recerca en Teledetecció
Jazyk: angličtina
Rok vydání: 2003
Předmět:
Zdroj: UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
Recercat. Dipósit de la Recerca de Catalunya
instname
DOI: 10.1049/el:20031164
Popis: The dynamic range and error performance of the diode power detector used to denormalise the digital correlations in interferometric radiometers is analysed by means of a second-order model of the diode response. This gives an easy method to establish system dynamic range as a trade-off between both the error contribution of measurement uncertainty and diode nonlinearity. The method is illustrated by analysing the power measurement system of the MIRAS-SMOS instrument.