3-Tesla MRI of deep brain stimulation patients: safety assessment of coils and pulse sequences
Autor: | Robert Chen, Eugen Hlasny, Alexandre Boutet, Adrian P. Crawley, Ileana Hancu, Manish Ranjan, Andres M. Lozano, Walter Kucharczyk, Ailish Coblentz, David S. Xu, Utpal Saha, Warren D. Foltz, Francesco Sammartino |
---|---|
Rok vydání: | 2020 |
Předmět: |
Male
Hot Temperature Deep brain stimulation Deep Brain Stimulation medicine.medical_treatment Population Neuroimaging Imaging phantom 030218 nuclear medicine & medical imaging Contraindications Procedure 03 medical and health sciences 0302 clinical medicine Electric Impedance medicine Humans education Lead (electronics) Aged education.field_of_study medicine.diagnostic_test Phantoms Imaging Pulse (signal processing) business.industry Specific absorption rate Magnetic resonance imaging Middle Aged Magnetic Resonance Imaging Neuromodulation (medicine) Electrodes Implanted Female business 030217 neurology & neurosurgery Biomedical engineering |
Zdroj: | Journal of Neurosurgery. 132:586-594 |
ISSN: | 1933-0693 0022-3085 |
DOI: | 10.3171/2018.11.jns181338 |
Popis: | OBJECTIVEPhysicians are more frequently encountering patients who are treated with deep brain stimulation (DBS), yet many MRI centers do not routinely perform MRI in this population. This warrants a safety assessment to improve DBS patients’ accessibility to MRI, thereby improving their care while simultaneously providing a new tool for neuromodulation research.METHODSA phantom simulating a patient with a DBS neuromodulation device (DBS lead model 3387 and IPG Activa PC model 37601) was constructed and used. Temperature changes at the most ventral DBS electrode contacts, implantable pulse generator (IPG) voltages, specific absorption rate (SAR), and B1+rms were recorded during 3-T MRI scanning. Safety data were acquired with a transmit body multi-array receive and quadrature transmit-receive head coil during various pulse sequences, using numerous DBS configurations from “the worst” to “the most common.”In addition, 3-T MRI scanning (T1 and fMRI) was performed on 41 patients with fully internalized and active DBS using a quadrature transmit-receive head coil. MR images, neurological examination findings, and stability of the IPG impedances were assessed.RESULTSIn the phantom study, temperature rises at the DBS electrodes were less than 2°C for both coils during 3D SPGR, EPI, DTI, and SWI. Sequences with intense radiofrequency pulses such as T2-weighted sequences may cause higher heating (due to their higher SAR). The IPG did not power off and kept a constant firing rate, and its average voltage output was unchanged. The 41 DBS patients underwent 3-T MRI with no adverse event.CONCLUSIONSUnder the experimental conditions used in this study, 3-T MRI scanning of DBS patients with selected pulse sequences appears to be safe. Generally, T2-weighted sequences (using routine protocols) should be avoided in DBS patients. Complementary 3-T MRI phantom safety data suggest that imaging conditions that are less restrictive than those used in the patients in this study, such as using transmit body multi-array receive coils, may also be safe. Given the interplay between the implanted DBS neuromodulation device and the MRI system, these findings are specific to the experimental conditions in this study. |
Databáze: | OpenAIRE |
Externí odkaz: |