Periodic Spirometry in Occupational Setting

Autor: Artak Hakobyan, Lu-Ann Beeckman-Wagner, Eva Hnizdo, James L. Fleming
Rok vydání: 2011
Předmět:
Zdroj: Journal of Occupational & Environmental Medicine. 53:1205-1209
ISSN: 1076-2752
DOI: 10.1097/jom.0b013e31823078b8
Popis: Objective: Effectiveness of periodic spirometry in medical monitoring depends on spirometry quality. We describe an intervention on spirometry quality and its impact on accuracy and precision of longitudinal measurements. Methods: The intervention was conducted from 2005 to 2010 in a monitoring program involving approximately 2500 firefighters. Intervention supported adherence to 2005 American Thoracic Society/European Respiratory Society recommendations through monitoring of spirometry quality and longitudinal data precision, technician training, change of spirometer, and quality control. Results: The percentage of forced vital capacity tests meeting the American Thoracic Society/European Respiratory Society criteria increased from 60% to 95% and the mean longitudinal forced expiratory volume in 1 second within-person variation decreased from 6% to 4%. The increased accuracy and precision of measurements and estimated rates of forced expiratory volume in 1 second decline were statistically significant. Conclusion: Monitoring of quality and data precision helped to recognize the need for intervention. The intervention improved accuracy and precision of spirometry measurements and their usefulness.
Databáze: OpenAIRE