Intra- and inter-rater reliability in the cross-sectional area of feline lumbar epaxial musculature evaluated via abdominal CT scan
Autor: | Eric M. Green, Valerie J. Parker, Laura H Rayhel, Shasha Bai, Jessica M Quimby |
---|---|
Rok vydání: | 2019 |
Předmět: |
040301 veterinary sciences
Abdominal ct 030204 cardiovascular system & hematology Area measurement Cachexia 0403 veterinary science 03 medical and health sciences 0302 clinical medicine Lumbar Abdomen medicine Animals Muscle Skeletal Small Animals Reliability (statistics) Retrospective Studies business.industry Lumbosacral Region Reproducibility of Results 04 agricultural and veterinary sciences medicine.disease Muscle atrophy Inter-rater reliability Sarcopenia Cats medicine.symptom Tomography X-Ray Computed business Nuclear medicine |
Zdroj: | Journal of Feline Medicine and Surgery. 22:721-728 |
ISSN: | 1532-2750 1098-612X |
DOI: | 10.1177/1098612x19880997 |
Popis: | Objectives The aim of this study was to evaluate the intra- and inter-rater reliability of epaxial muscle cross-sectional area measurement on feline CT images and to determine the relationship between normalized epaxial muscle area (EMA) and subjective muscle condition score (MCS). Methods Feline transverse CT images including the junction of the 13th thoracic vertebrae/13th rib head were retrospectively reviewed. Right and left epaxial muscle circumference and vertebral body height were measured and an average normalized EMA (ratio of epaxial area:vertebral height) was calculated for each image. Measurements were performed by three individuals blinded to the clinical data and were repeated 1 month later. Intra- and inter-rater reliability of EMA was assessed with concordance correlation coefficient (CCC), and Bland–Altman analysis was performed to assess bias and limits of agreement (LoA) between and within observers at different time points. In cats for which MCS data were available, EMA was compared between differing MCSs via the Kruskal–Wallis test, with Bonferroni-corrected Wilcoxon rank-sum post-hoc analysis. Results In total, 101 CT scans met the inclusion criteria for reliability analysis, 29 of which had muscle condition information available for analysis. Intra-rater EMA CCC ranged from 0.84 to 0.99 with minimal bias (range –0.16 to 0.08) and narrow LoA. Inter-rater EMA CCC ranged from 0.87 to 0.94, bias was larger (range –0.46 to 0.66) and LoA were wider when assessed between observers. Median EMA was significantly lower in cats with severe muscle atrophy (2.76, range 1.28–3.96) than in all other MCS groups ( P Conclusions and relevance Measurement of EMA on CT showed strong intra-rater reliability, and median EMA measurements were significantly lower in cats with severe muscle wasting, as assessed on physical examination. Further studies correlating EMA to lean muscle mass in cats are needed to determine whether this method may be useful to quantify muscle mass in patients undergoing a CT scan. |
Databáze: | OpenAIRE |
Externí odkaz: |