Calculation of beta-ray dose distributions from ophthalmic applicators and comparison with measurements in a model eye
Autor: | J Hokkanen, P Sipila, W G. Cross, F.A. Mourtada, H. Järvinen, Stefaan Vynckier, Christopher G. Soares |
---|---|
Rok vydání: | 2001 |
Předmět: |
Eye Diseases
Brachytherapy Monte Carlo method Biophysics Dose distribution Eye Biophysical Phenomena Ruthenium Optics Planar Beta particle Dosimetry Rhodium Yttrium Radioisotopes Radiometry Radioisotopes Physics Models Statistical Phantoms Imaging business.industry Scattering X-Ray Film Attenuation Water General Medicine Beta Particles Monte carlo code Strontium Radioisotopes business Monte Carlo Method |
Zdroj: | Medical Physics. 28:1385-1396 |
ISSN: | 0094-2405 |
DOI: | 10.1118/1.1376442 |
Popis: | Dose distributions throughout the eye, from three types of beta-ray ophthalmic applicators, were calculated using the EGS4, ACCEPT 3.0, and other Monte Carlo codes. The applicators were those for which doses were measured in a recent international intercomparison [Med. Phys. 28, 1373 (2001)], planar applicators of Ru-106-Rh-106 and Sr-90-Y-90 and a concave Ru-106-Rh-106 applicator. The main purpose was to compare the results of the various codes with average experimental values. For the planar applicators, calculated and measured doses on the source axis agreed within the experimental errors ( |
Databáze: | OpenAIRE |
Externí odkaz: |