Technical Note: Implications of using EGSnrc instead of EGS4 for extracting electron stopping powers from measured energy spectra
Autor: | Frédéric Tessier, Carl K. Ross |
---|---|
Rok vydání: | 2020 |
Předmět: |
Work (thermodynamics)
Monte Carlo method Physics::Medical Physics energy to create an ion pair electron energy spectra Nal detector Electrons Electron Spectral line 030218 nuclear medicine & medical imaging Electron Transport 03 medical and health sciences Cross section (physics) 0302 clinical medicine Stopping power (particle radiation) electronic stopping powers Radiometry EGS4 Physics Elastic scattering Detector General Medicine Computational physics EGSnrc 030220 oncology & carcinogenesis Monte Carlo Method Algorithms |
Zdroj: | Medical physicsREFERENCES. 48(4) |
ISSN: | 2473-4209 |
Popis: | Purpose: NRC Report PIRS‐0626 (https://doi.org/10.4224/40000364) describes how measured electron energy deposition spectra can be used to determine the electronic stopping power. The stopping power is obtained by comparing measured spectra with spectra calculated using Monte Carlo techniques. The stopping powers reported in PIRS‐0626 were obtained using the EGS4 Monte Carlo code. Since then, the EGSnrc code has been released which has more accurate electron transport algorithms. We calculate the effect on the measured stopping powers of using EGSnrc instead of EGS4. Method: The EGS4 spectra calculated in PIRS‐0626 were based on 4 X 10⁵ primary electron histories. We first show that those spectra, calculated in 1997, are consistent with current EGS4 spectra calculated using 10⁸ histories. EGSnrc spectra are also calculated using 10⁸ histories and these high‐precision spectra are compared to extract any energy difference. The energy differences between the spectra are used to estimate the effect on the measured electronic stopping powers. Results: The energy differences depend on the absorber material, the absorber thickness and the beam energy. The improved electron elastic scattering cross section of EGSnrc accounts for only part of the difference between the two codes. The effect on the extracted stopping power is largest for the lowest electron energies and can be as large as 0.9%. The calculated spectra show differences for lower energies, with the EGSnrc spectra having a larger proportion of low‐energy electrons. Conclusion: The differences introduced by using EGSnrc instead of EGS4 can affect the estimated stopping power by almost 1% in the worst case but generally the effect is much smaller. We report corrections that can be applied to all the stopping power data in PIRS‐0626. An experiment to measure the average energy to create an ion pair in air, Wₐᵢᵣ, using aluminum detectors will provide an interesting test of the aluminum stopping power data as reported in PIRS‐0626 and revised by this work. |
Databáze: | OpenAIRE |
Externí odkaz: |