RESULTS OF CALCULATION-EXPERIMENTAL INVESTIGATIONS OF ELECTRO-THERMAL RESISTIBILITY OF SHEET STEEL SAMPLES TO ACTION OF RATIONED COMPONENTS OF PULSED CURRENT OF ARTIFICIAL LIGHTING

Autor: V. V. Kniaziev, M. I. Baranov, V. I. Kravchenko, S. V. Rudakov
Jazyk: angličtina
Rok vydání: 2016
Předmět:
Engineering
impulse current generator of artificial lightning
Acoustics
Fire safety
основні компоненти струму блискавки
генератор імпульсного струму штучної блискавки
плоский сталевий зразок
електротермічна блискавкостійкість
Impulse (physics)
01 natural sciences
621.3.022: 621.319.53
0103 physical sciences
Sheet steel
flat steel sample
010302 applied physics
Artificial light
010308 nuclear & particles physics
business.industry
electro-thermal resistibility to lightning
Electrical engineering
main components of lightning current
impulse current generator of artificial lightning
flat steel sample
electrothermal resistibility to lightning

основные компоненты тока молнии
генератор импульсного тока искусственной молнии
плоский стальной образец
электротермическая молниестойкость
TK1-9971
Microsecond
Amplitude
main components of lightning current
Pulse current
Electrical engineering. Electronics. Nuclear engineering
business
Keyhole
Zdroj: Electrical engineering & Electromechanics, Iss 3, Pp 40-49 (2016)
Electrical Engineering & Electromechanics; № 3 (2016): Electrical Engineering & Electromechanics №3 2016; 40-49
Электротехника и Электромеханика; № 3 (2016): Электротехника и Электромеханика №3 2016; 40-49
Електротехніка і Електромеханіка; № 3 (2016): Електротехніка і Електромеханіка №3 2016; 40-49
ISSN: 2309-3404
2074-272X
Popis: Purpose. Calculation and experimental researches of the electro-thermal resistibility of the steel sheet samples to action standard pulse current components of the artificial lightning with amplitude-time parameters (ATP), corresponded the requirements of normative documents of USA for SAE ARP 5412 & SAE ARP 5416. Methodology. Electrophysics bases of technique of high tensions and large impulsive currents (LIC), and also scientific and technical bases of planning of devices of high-voltage impulsive technique and measuring in them LIC. Сurrent amplitude ImA=±200 kA (with a tolerance of ±10 %); current action integral JA=2∙106 A2·s (with a tolerance of ±20 %); time, corresponding to the amplitude of the current ImA, tmA≤50 microseconds; the duration of the current flow τpA≤500 microseconds. Results. The results of the evaluation of the calculated and experimental studies of electro-thermal resistance of the samples of plates measuring 0,5 m ´ 0,5 m stainless steel 1 mm thickness to the action on them artificial lightning impulse currents with rationed ATP on the requirements of normative documents of USA for SAE ARP 5412 & SAE ARP 5416. A pulse A- component have a first amplitude 192 kA, the corresponding time of 34 μs, and the duration aperiodic component amplitude 804 A, corresponding to the time 9 ms. It has been shown that the long C- component current of artificial lightning can lead to keyhole these samples. The diameter of the holes in this thin steel sheet, which is formed during the flow of current C- components can reach 15 mm. The results of calculation and experiment agree within 28 %. Originality. For the first time in world practice on the generator large pulsed currents experimental studies of resistibility of sheet steel samples to the action of artificial lightning currents with critical parameters. Practical value. Using the results obtained in the practice of lightning protection will significantly improve the functionality and fire safety of different objects in conditions of exposure to linear lightning.
Приведены результаты оценочных расчетных и экспериментальных исследований электротермической стойкости опытных образцов пластин размером 0,5 м ´ 0,5 м из нержавеющей стали толщиной 1 мм к воздействию на них импульсных токов искусственной молнии с нормированными по требованиям нормативных документов США SAE ARP 5412 и SAE ARP 5416 амплитудно-временными параметрами (АВП). Использовались колебательная импульсная А- компонента с первой амплитудой 192 кА, соответствующей времени 34 мкс, и апериодическая длительная С- компонента амплитудой 804 А, соответствующей времени 9 мс. Показано, что длительная С- компонента тока искусственной молнии с нормированными АВП может приводить к сквозному проплавлению указанных образцов.
Наведено результати оціночних розрахункових і експериментальних досліджень електротермічної стійкості дослідних зразків пластин розміром 0,5 м ´ 0,5 м з нержавіючої сталі товщиною 1 мм до дії на них імпульсних струмів штучної блискавки з нормованими за вимогами нормативних документів США SAE ARP 5412 і SAE ARP 5416 амплітудно-часовими параметрами (АЧП). Використовувалися коливальна імпульсна А- компонента з першої амплітудою 192 кА, що відповідає часу 34 мкс, і аперіодична тривала С- компонента амплітудою 804 А, що відповідає часу 9 мс. Показано, що тривала С- компонента струму штучної блискавки з нормованими АЧП може призводити до наскрізного проплавлення зазначених зразків.