RESULTS OF CALCULATION-EXPERIMENTAL INVESTIGATIONS OF ELECTRO-THERMAL RESISTIBILITY OF SHEET STEEL SAMPLES TO ACTION OF RATIONED COMPONENTS OF PULSED CURRENT OF ARTIFICIAL LIGHTING
Autor: | V. V. Kniaziev, M. I. Baranov, V. I. Kravchenko, S. V. Rudakov |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2016 |
Předmět: |
Engineering
impulse current generator of artificial lightning Acoustics Fire safety основні компоненти струму блискавки генератор імпульсного струму штучної блискавки плоский сталевий зразок електротермічна блискавкостійкість Impulse (physics) 01 natural sciences 621.3.022: 621.319.53 0103 physical sciences Sheet steel flat steel sample 010302 applied physics Artificial light 010308 nuclear & particles physics business.industry electro-thermal resistibility to lightning Electrical engineering main components of lightning current impulse current generator of artificial lightning flat steel sample electrothermal resistibility to lightning основные компоненты тока молнии генератор импульсного тока искусственной молнии плоский стальной образец электротермическая молниестойкость TK1-9971 Microsecond Amplitude main components of lightning current Pulse current Electrical engineering. Electronics. Nuclear engineering business Keyhole |
Zdroj: | Electrical engineering & Electromechanics, Iss 3, Pp 40-49 (2016) Electrical Engineering & Electromechanics; № 3 (2016): Electrical Engineering & Electromechanics №3 2016; 40-49 Электротехника и Электромеханика; № 3 (2016): Электротехника и Электромеханика №3 2016; 40-49 Електротехніка і Електромеханіка; № 3 (2016): Електротехніка і Електромеханіка №3 2016; 40-49 |
ISSN: | 2309-3404 2074-272X |
Popis: | Purpose. Calculation and experimental researches of the electro-thermal resistibility of the steel sheet samples to action standard pulse current components of the artificial lightning with amplitude-time parameters (ATP), corresponded the requirements of normative documents of USA for SAE ARP 5412 & SAE ARP 5416. Methodology. Electrophysics bases of technique of high tensions and large impulsive currents (LIC), and also scientific and technical bases of planning of devices of high-voltage impulsive technique and measuring in them LIC. Сurrent amplitude ImA=±200 kA (with a tolerance of ±10 %); current action integral JA=2∙106 A2·s (with a tolerance of ±20 %); time, corresponding to the amplitude of the current ImA, tmA≤50 microseconds; the duration of the current flow τpA≤500 microseconds. Results. The results of the evaluation of the calculated and experimental studies of electro-thermal resistance of the samples of plates measuring 0,5 m ´ 0,5 m stainless steel 1 mm thickness to the action on them artificial lightning impulse currents with rationed ATP on the requirements of normative documents of USA for SAE ARP 5412 & SAE ARP 5416. A pulse A- component have a first amplitude 192 kA, the corresponding time of 34 μs, and the duration aperiodic component amplitude 804 A, corresponding to the time 9 ms. It has been shown that the long C- component current of artificial lightning can lead to keyhole these samples. The diameter of the holes in this thin steel sheet, which is formed during the flow of current C- components can reach 15 mm. The results of calculation and experiment agree within 28 %. Originality. For the first time in world practice on the generator large pulsed currents experimental studies of resistibility of sheet steel samples to the action of artificial lightning currents with critical parameters. Practical value. Using the results obtained in the practice of lightning protection will significantly improve the functionality and fire safety of different objects in conditions of exposure to linear lightning. Приведены результаты оценочных расчетных и экспериментальных исследований электротермической стойкости опытных образцов пластин размером 0,5 м ´ 0,5 м из нержавеющей стали толщиной 1 мм к воздействию на них импульсных токов искусственной молнии с нормированными по требованиям нормативных документов США SAE ARP 5412 и SAE ARP 5416 амплитудно-временными параметрами (АВП). Использовались колебательная импульсная А- компонента с первой амплитудой 192 кА, соответствующей времени 34 мкс, и апериодическая длительная С- компонента амплитудой 804 А, соответствующей времени 9 мс. Показано, что длительная С- компонента тока искусственной молнии с нормированными АВП может приводить к сквозному проплавлению указанных образцов. Наведено результати оціночних розрахункових і експериментальних досліджень електротермічної стійкості дослідних зразків пластин розміром 0,5 м ´ 0,5 м з нержавіючої сталі товщиною 1 мм до дії на них імпульсних струмів штучної блискавки з нормованими за вимогами нормативних документів США SAE ARP 5412 і SAE ARP 5416 амплітудно-часовими параметрами (АЧП). Використовувалися коливальна імпульсна А- компонента з першої амплітудою 192 кА, що відповідає часу 34 мкс, і аперіодична тривала С- компонента амплітудою 804 А, що відповідає часу 9 мс. Показано, що тривала С- компонента струму штучної блискавки з нормованими АЧП може призводити до наскрізного проплавлення зазначених зразків. |
Databáze: | OpenAIRE |
Externí odkaz: |