Vasopressor use after initial damage control laparotomy increases risk for anastomotic disruption in the management of destructive colon injuries

Autor: Ronald F. Sing, Andrew M. Nunn, A. Britton Christmas, Blair A. Wormer, Peter E. Fischer, Lindsay A. Gibeault, John M. Green
Rok vydání: 2013
Předmět:
Zdroj: The American Journal of Surgery. 206:900-903
ISSN: 0002-9610
Popis: Background Management of destructive colon injuries during damage control (DC) laparotomy is debated. The authors reviewed a single institution's experience with destructive colon injuries to identify risk factors for anastomotic failure after colon reconstruction. Methods The authors identified all trauma patients sustaining destructive colon injuries between 2002 and 2011 from their medical center's trauma registry. Anastomotic leak was defined as suture or staple line disruption or enteral fistula formation. Results Of 171 identified patients, 68 had DC procedures, 41 (60%) had subsequent anastomoses performed during the same hospitalization, and 27 (40%) were diverted. The colon anastomotic leak rate in patients who underwent DC laparotomy was higher than in patients who were reconstructed at the primary operation in a non-DC setting (17% vs 6%, P = .09). The use of vasopressors after the initial DC operation more than quadrupled the leak rate to 50% ( P = .02). Conclusions Colonic anastomotic disruptions yield deadly consequences, and diversion rather than anastomosis should be used in patients who require vasopressor support after the initial DC procedure.
Databáze: OpenAIRE