Assessment of Need for Transport Tubes When Continuously Monitoring for Radioactive Aerosals
Autor: | John C. Rodgers, Jeffrey J. Whicker, Ricky C. Lopez |
---|---|
Rok vydání: | 1999 |
Předmět: |
Meteorology
Epidemiology Health Toxicology and Mutagenesis Instrumentation chemistry.chemical_element complex mixtures Nuclear Reactors Radiation Monitoring Humans Radiology Nuclear Medicine and imaging Extraction (military) Remote sensing Aerosols Sampling (statistics) respiratory system Plutonium Ventilation Aerosol chemistry Air Pollutants Radioactive Evaluation Studies as Topic Measuring instrument Environmental science Particle Radiation monitoring Health Physics |
Zdroj: | Health Physics. 77:322-327 |
ISSN: | 0017-9078 |
DOI: | 10.1097/00004032-199909000-00012 |
Popis: | Aerosol transport tubes are often used to draw aerosol from desirable sampling locations to nearby air sampling equipment that cannot be placed at that location. In many plutonium laboratories at Los Alamos National Laboratory, aerosol transport tubes are used to transport aerosol from the front of room ventilation exhaust registers to continuous air monitors (CAMs) that are mounted on nearby walls. Transport tubes are used because past guidance suggests that extraction of aerosol samples from exhaust locations provides the most sensitive and reliable detection under conditions where the rooms have unpredictable release locations and significant spatial variability in aerosol concentrations after releases, and where CAMs cannot be located in front of exhaust registers without blocking worker walkways. Despite designs to minimize particle loss in tubes, aerosol transport model predictions suggest losses occur lowering the sensitivity of CAMs to accidentally released plutonium aerosol. The goal of this study was to test the hypotheses that the reliability, speed, and sensitivity of aerosol detection would be equal whether the sample was extracted from the front of the exhaust register or from the wall location of CAMs. Polydisperse oil aerosols were released from multiple locations in two plutonium laboratories to simulate plutonium aerosol releases. Networked laser particle counters (LPCs) were positioned to simultaneously measure time-resolved aerosol concentrations at each exhaust register (representative of sampling with transport tubes) and at each wall-mounted CAM location (representative of sampling without transport tubes). Results showed no significant differences in detection reliability, speed, or sensitivity for LPCs positioned at exhaust locations when compared to LPCs positioned at the CAM wall location. Therefore, elimination of transport tubes would likely improve CAM performance. |
Databáze: | OpenAIRE |
Externí odkaz: |