Assessment of Corneal Keratometric and Astigmatism Measurements Using Verion System and Other Instruments in Cataract Patient
Autor: | Giacomo Savini, Benhao Song, Yun-e Zhao, Hengli Lian, Jinhai Huang, Qinmei Wang, Yana Fu, Xinxin Yu |
---|---|
Rok vydání: | 2018 |
Předmět: |
Adult
Male medicine.medical_specialty Biometry Scheimpflug principle Diagnostic Techniques Ophthalmological Cataract law.invention Cornea Young Adult 03 medical and health sciences Cellular and Molecular Neuroscience 0302 clinical medicine law Ophthalmology Humans Medicine Prospective Studies Pentacam hr Aged Aged 80 and over Cataract patient Keratometer business.industry Astigmatism Reproducibility of Results Middle Aged Sensory Systems Meridian (perimetry visual field) 030221 ophthalmology & optometry Female business Corneal astigmatism 030217 neurology & neurosurgery |
Zdroj: | Current Eye Research. 43:1205-1214 |
ISSN: | 1460-2202 0271-3683 |
DOI: | 10.1080/02713683.2018.1488264 |
Popis: | To compare keratometry and corneal astigmatism measurements obtained by the Verion Image Guided System to those obtained by automated keratometry (IOLMaster), manual keratometry (YZ38, Suzhou 66 visual Polytron Technologies Inc., China), and Scheimpflug imaging (Pentacam HR) in eyes with cataract.A total of 149 cataractous eyes of 149 patients were examined and categorized as low astigmatism (1.0 D, N = 50), moderate astigmatism (1.0-2.0 D, N = 49), and high astigmatism (2.0 D, N = 50). The flattest and the steepest keratometric values (Kf and Ks), the magnitude of astigmatism (Ast), the orientation of the steepest meridian (Axis), and power vectors JKeratometry readings (Kf, Ks, and Km) obtained by the Verion system showed statistically significant differences as compared to the other three devices. The magnitude of astigmatism (Ast) measured by the Verion (1.50 ± 0.85 D) was similar to that measured by the YZ38 (1.45 ± 0.82 D, P = 0.110) and slightly lower than that by the IOLMaster (1.56 ± 0.87 D, P = 0.014), but much higher than that by the Pentacam (1.36 ± 0.81 D, P = 0.000) significantly. However, no statistically significant differences were observed in the JKeratometric and astigmatic results obtained with Verion were not completely interchangeable with those obtained with IOLMaster, manual keratometry, and Pentacam. The individual differences in power and orientation of the corneal cylinder should be considered while selecting the appropriate toric intraocular lens. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |