Determination of sodium N-methyldithiocarbamate (metham sodium) and methyl isothiocyanate in aqueous samples by high-performance liquid chromatography using a micellar mobile phase
Autor: | Gordon F. Kirkbright, Frank G. P. Mullins |
---|---|
Rok vydání: | 1987 |
Předmět: |
Sodium
chemistry.chemical_element Fresh Water Biochemistry High-performance liquid chromatography Micelle Analytical Chemistry chemistry.chemical_compound Column chromatography Isothiocyanates Thiocarbamates Electrochemistry Environmental Chemistry Water Pollutants Chromatography High Pressure Liquid Micelles Spectroscopy Detection limit Aqueous solution Chromatography Sewage Phosphate Fungicides Industrial chemistry Methyl isothiocyanate Spectrophotometry Ultraviolet Thiocyanates Water Pollutants Chemical |
Zdroj: | The Analyst. 112:701 |
ISSN: | 1364-5528 0003-2654 |
DOI: | 10.1039/an9871200701 |
Popis: | A high-performance liquid chromatographic procedure was developed for the simultaneous determination of the fungicides sodium N-methyldithiocarbamate and methyl isothiocyanate. These fungicides were separated on a reversed-phase octadecyl bonded column with micellar hexadecyltrimethylammonium bromide in an eluent of methanol-water (50 + 50 V/V) buffered to pH 6.8 (10 mM phosphate). Detection was carried out at 247 nm with a UV detector. Recoveries of standards added to pond water and untreated sewage were >92% and >88%, respectively, for both fungicides. The detection limits for sodium N-methyldithiocarbamate and methyl isothiocyanate are 70 µg dm–3(p.p.b.) and 1 µg dm–3(p.p.b.), respectively. |
Databáze: | OpenAIRE |
Externí odkaz: |