Determination of Boron in Silicon Carbide by ICP-OES and ICP-MS after Sample Preparation using Pyrohydrolysis
Autor: | Aline L. H. Muller, Cristiano C. Muller, Erico M.M. Flores, Valderi L. Dressler, Edson I. Muller, Thieli Schaefer Nunes |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2015 |
Předmět: |
Detection limit
Materials science pyrohydrolysis Water flow Analytical chemistry chemistry.chemical_element General Chemistry Certified reference materials chemistry silicon carbide Inductively coupled plasma atomic emission spectroscopy ICP-OES ICP-MS Sample preparation Inductively coupled plasma Boron boron Inductively coupled plasma mass spectrometry |
Zdroj: | Journal of the Brazilian Chemical Society, Volume: 26, Issue: 1, Pages: 110-116, Published: JAN 2015 Journal of the Brazilian Chemical Society v.26 n.1 2015 Journal of the Brazilian Chemical Society Sociedade Brasileira de Química (SBQ) instacron:SBQ |
Popis: | Pyrohydrolysis was used for sample preparation of silicon carbide (SiC) and subsequent determination of B using inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS). Important parameters for pyrohydrolysis method as temperature, air and water flow rates, reaction time and use of V2O5 were evaluated. In addition, a study of W spectral interference on B emission lines was evaluated for ICP-OES determination. Accuracy was evaluated using certified reference material (CRM BAM S003) and bias value lower than 1% between the certified and determined value was achieved. Limit of detection (LOD) of 0.010 μg g−1 was obtained using pyrohydrolysis and ICP-MS. Pyrohydrolysis is a very simple sample preparation method that allowed the use of deionized water as absorbing solution for B determination in SiC. A pirohidrólise foi utilizada no preparo de amostras de carbeto de silício (SiC) para posterior determinação de B usando espectrometria de emissão óptica com plasma indutivamente acoplado (ICP-OES) e espectrometria de massa com plasma indutivamente acoplado (ICP-MS). Parâmetros importantes como temperatura, fluxo de água e ar, tempo de reação e uso de V2O5 foram avaliados. Adicionalmente, foi avaliada a interferência de W sobre as linhas de emissão de B durante as determinações por ICP-OES. A exatidão foi avaliada usando material de referência certificado (CRM BAM S003) e valor de bias inferior a 1% foi encontrado entre os valores de referência e obtido experimentalmente. Limite de detecção (LOD) de 0,010 μg g−1 foi obtido usando pirohidrólise e determinação por ICP-MS. A pirohidrólise é um método de preparo de amostras simples que permitiu a utilização de água deionizada como solução absorvedora para a determinação de B em SiC. |
Databáze: | OpenAIRE |
Externí odkaz: |