030204 cardiovascular system & hematology Microbial contamination Fluoroscopy dose Article 03 medical and health sciences Adenosine Triphosphate 0302 clinical medicine Protective Clothing fashion Physiology (medical) Lead garments Hospital-acquired infection ATP test medicine Humans 030212 general & internal medicine Lead (electronics) Surgical sterility ATP testing business.industry medicine.disease Disinfection Electrophysiology fashion.garment Anesthesia Lead apron Laboratories Cardiology and Cardiovascular Medicine business |
Zdroj: | Journal of Interventional Cardiac Electrophysiology |
ISSN: | 1572-8595 1383-875X |
DOI: | 10.1007/s10840-020-00936-2 |
Popis: | Purpose Electrophysiology procedures pose infection risk and require surgical room sterility. Currently, there is no universally approved protocol for disinfecting lead garments in the electrophysiology laboratory. This study explores the feasibility of using ATP testing to assess the microbial burden of lead aprons and evaluates the impact of a sanitary intervention. Methods Adenosine triphosphate (ATP) testing is a well-established hospital standard to quantify biological matter on a surface and, by proxy, the microbial burden. It is measured in RLU (relative light units). Pre-intervention ATP testing was performed on 34 lead garments after use for electrophysiology procedures. The thyroid collar, mid-chest vest, and left axillary areas of the garments were swabbed using a Hygiena SystemSure II luminometer with ATP swabs (Hygiena, Camarillo, CA). These sites were then disinfected with disinfectant wipes (PDI Super Sani-cloth Germicidal Disposable Wipe) and ATP testing was repeated. Results The mean duration of garment wear was 213 min. The thyroid collars had the highest mean RLU before intervention, followed by the mid-chest vest and the left axillary areas. The intervention was found to significantly decrease ATP readings for all three sites (p = 0.0002, p = 0.0001, p = 0.0002 respectively). Linear regression modeling to assess the impact of intervention showed a significant correlation with pre-intervention ATP values for all three sites but no correlation with fluoroscopy time, fluoroscopy dose, or total time spent within the procedure. Conclusions Lead garments harbor microbial contamination after use according to ATP testing. A sanitary intervention can decontaminate lead garments and potentially reduce rates of hospital infection. |
Databáze: | OpenAIRE |
Externí odkaz: |